• This operators and users manual is in English. • It contains important safety guidelines and instructions. • Should you be unsure at any stage, or unable to understand the contents within this manual you must seek expert advice. • Le mode d’emploi est en anglais. • Il contient des instructions et mesures de sécurité importantes. • En cas de doute, ou s’il vous est impossible de comprendre le contenu du monde d’emploi, demandez conseil à un expert.
contents Figures ON/OFF functions (fig.1) 05 Game timer (fig.2) 13 External menus whilst in SAFE (fig.3) 14-15 PIN number locking/unlocking (fig.4) 16 TM External LCD C.O.P.S. 18 menu whilst in LIVE (fig.5) Internal tournament LCD menus (fig.6) 21 Internal tournament LCD menus - PIN number programming (fig.7) 23 Internal tournament LCD menus - Text programming (fig.8) 24 25 PCB Layout TM Wiring connections: Intellifeed/Charger /14 way valve/Battery and C.O.P.S.
TM • The ANGEL iR3TM is not a toy. • Careless or improper use, including failure to follow instructions and warnings within this Operator’s Manual and attached to the ANGEL iR3TM, could cause death or serious injury. • Do not remove or deface any warnings attached to the ANGEL iR3TM. • Paintball industry standard eye/face/ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 ( USA) or CE standard (Europe) must be worn by user and any person within range.
SWITCHING ON YOUR ANGEL iR3 TM ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • • • • Ensure a barrel blocking device is fitted to the ANGEL iR3TM Ensure the hopper is removed from the ANGEL iR3TM Ensure that there are no paintballs in the ANGEL iR3TM Paintball industry standard eye/face/ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 ( USA) or CE standard (Europe) must be worn by user and any person within range.
TM To switch power OFF: Move the toggle switch to the right toward the centre of the marker. Switching power OFF results in complete isolation of the electronics. To switch power ON: Move the toggle switch to the left On/off power saving mode SAFE To make ANGEL – LIVE. Press and hold the red button for 2 secs. Display will flash ‘LIVE ANGEL’ unless personalised text has been added, then it will flash ‘LIVE’ + the added text alternately. s SAFE Marker unable to fire.
operating instructions • A 1-hour charge at 12.5V DC will give sufficient power for approximately 16,000 consecutive shots with the hopper also being powered. • The ANGEL iR3TM will continue to use power even when in power saving sleep mode and the battery will discharge in approximately 288 hours even if the marker is not being used. To save the charge the isolator switch must be switched OFF to isolate the battery.
• • • • • • • • • • • • TM Ensure a barrel blocking devise is fitted to the Angel iR3TM. Ensure the hopper is removed from the Angel iR3TM. Ensure there are no paintballs in the Angel iR3TM. Ensure the Angel iR3TM is switched off via the isolating switch at the rear of the marker prior to fitting your first stage regulator.
operating instructions FITTING THE HOPPER INTELLIFEEDTM (OPTIONAL EXTRA) ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • • • • Ensure Ensure Ensure Ensure the ANGEL iR3TM is switched off via the isolating switch on the rear of the marker a barrel blocking device is fitted to the ANGEL iR3TM the hopper is removed from the ANGEL iR3TM that there are no paintballs in the ANGEL iR3TM The ANGEL iR3TM has the ability to power motorized hoppers with the agitation and electrical sup
TM • Do not fire the ANGEL iR3TM with the breech open or without the bolt in the breech, as high pressure gas will be admitted. • Do not fire the ANGEL iR3TM with the pull knob in the unlocked position. • Ensure the ANGEL iR3TM is in “SAFE” mode or the isolator switch is in the OFF position. • Pull the ‘Pull knob’ and rotate 90 degrees so that the knob remains in the unlocked position. • Swing out the Rotor Breech block so that the bolt is exposed.
ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • Ensure a barrel blocking device is fitted to the ANGEL iR3TM • Ensure the hopper is removed from the ANGEL iR3TM • Ensure that there are no paintballs in the ANGEL iR3TM The ANGEL iR3TM has a number of features that can be adjusted to suit your individual needs. These features are designed to enhance your play and also to supply you with a wealth of information.
TM C.O.P.S.TM option is selected. Certain modes are capped or non-adjustable. The rate of fire should not be set greater than your feed system is capable of delivering. This cannot be changed by the external menu (See internal menu diagram fig.6 p21). See table on Modes for maximum allowable settings (p 21). Game timer with 3 interactive alarms (fig.2 page 13) The “vibes” timer incorporates 3 independent alarms that take the stress out of game play.
external LCD menus whilst in SAFE Hopper A (Activation) This allows the user to set the activation point of the hopper. It can be set to activate on the ROF level that you achieve. It can be set to the following parameters. A1 = Activates on every shot. A2 = Activates on a ROF of 2 shots or greater. A3 = Activates on a ROF of 3 shots or greater. A4 = Activates on a ROF of 4 shots or greater. Infra Red Menu This allows the user to select which menu to transmit to another Angel iR3TM.
Fetch (infra-red) Infrared menu Send (infra-red) Back light feature Cycles (total shots) feature Trip (shot counter) feature ID (unique identification number) ROF (rate of fire actually achieved by user feature) MROF (maximum rate of fire feature with C.O.P.S off) CMROF (maximum rate of fire feature with C.O.P.S on) Game timer feature Vibes (vibrator alarm feature) Mode feature (style of shooting) Dwell feature Hopper T (timer) Hopper A (activation) Temperature feature T.C.O.P.S. C.O.P.S.
SAFE SAFE To make marker SAFE press and hold button for 2 secs. Amber and green buttons remain operative for menus. LIVE THE MARKER IS LIVE AND CAPABLE OF DISCHARGING. OBSERVE ALL SAFETY INSTRUCTIONS & GUIDELINES. THE MARKER IS LIVE AND CAPABLE OF DISCHARGING. OBSERVE ALL SAFETY INSTRUCTIONS & GUIDELINES. To make marker LIVE press and hold button for 2 secs. LIVE Timer Armed - Vibes activates for 5 secs as confirmation. - Display flashes between the set time and LIVE.
s HUD s Back light s ON s CYCLES 00674 TRIP s 00674 Total shots s s Achieved rate of fire s ROF s 13 s I.D. number s 00000 ID Shot counter s s u 0 Reset to zero s ROF No sub-menu s 00000 ID Reset to zero s TRIP 00000 Factory reset only s CYCLES 00674 No Access s HUD On/Off s OFF ASTM s s Vibes game alarm s ON s s s HOPPER Valve dwell s 14 DWELL Firing mode SEMI s s Specification Hopper motor running time s TO.1 s s u 0.1-2.0 secs. In 0.
Amber and green buttons remain operative for menus. s s 15:00 TIMER Max rate of fire s MROF C 13 s 5:00 Game timer s s 1:00 Alarm 1. (icon will flash) s s 5:00 Alarm 2 s u Alarm 3 s s Defaults to ‘SAFE’ status after 10 sec. The marker is unable to fire when “SAFE’ or reading menus. Max rate of fire s s SAFE s In 30 sec increments. Default 5:00 s 5:30 Increments. Default 1:00 s 1:30 In 30 sec increments. Default 0:00 s 5:30 1-30 mins. In 30 sec increments.
s s 0---- Unique ID number displayed. 2---- s s s s s Confirm number entry using the external GREEN button. 246-- s s 246-- Confirm number entry using the external GREEN button. s Confirm number entry using the external GREEN button. 24--- Scroll through 2nd flashing digit using the external ORANGE button. s Scroll through 3rd flashing digit using the external ORANGE button. 2468- Confirm number entry using the external GREEN button.
ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • THIS MENU IS ONLY SETTABLE WHILST THE ANGEL iR3TM IS LIVE AND CAPABLE OF DISCHARGING. • Paintball industry standard eye/face/ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 ( USA) or CE standard (Europe) must be worn by user and any person within range. • Never point the Angel iR3TM at anything you do not intend to shoot. The ANGEL iR3 has the C.O.P.
Instructions to the following areas have changed in the user manual. See text below. BAS 1 = • Smaller window of opportunity for a paintball to fall into the breech. • Larger risk of chopping a paintball. BAS 20 = • Larger window of opportunity for a paintball to fall into the breech. • Smaller risk of chopping a paintball. s s COPS LIVE s The sensor is not affected by colour or surface finish of the paintballs and is designed to be unaffected by paint fill.
TM • Ensure a barrel blocking device is fitted to the ANGEL iR3TM • Ensure the hopper is removed from the ANGEL iR3TM • Ensure that there are no paintballs in the ANGEL iR3TM • The ANGEL iR3TM has a number of features that can be adjusted to suit your individual needs (fig. 6 page 21). These features that can change the performance of the gun are only accessible via the internal menu list. This is to ensure that they pass tournament and field operator requirements.
20/sec 20/sec 20/sec 20/sec 20/sec • MULTI = Multiplier • TT = TT multiplier Dwell feature (fig.6 page 21) Dwell controls the valve opening time. Longer dwell time uses more gas and generates more noise but allows the marker a greater tolerance to paint, temperature and pressure variables. Shorter dwell time uses less gas and reduces noise but is less tolerant of poor paint and pressure variables. Adjustment is only recommended if you wish to fine-tune your marker to specific accessories.
UK and USA specification s s Firing mode s s COPS s C.O.P.S. s s 77ºF s Temperature SAFE s s MROF 13 Max rate of fire possible without C.O.P.S. s s C13 s MROF s Max rate of fire possible with C.O.P.S. s s DWELL 14 Valve dwell s s s AUTOF s Only enabled if the specification permits modes of firing. Up to 26 available. s Press and hold both buttons for 2 seconds. C.O.P.S. test mode Drop 1 paintball into the breech. If a paintball is detected ‘PASS’ will be displayed.
internal tournament LCD menus T.C.O.P.S. (C.O.P.S.TM Test Feature) (fig.6 page 21) ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • Paintball industry standard eye/face/ear and head protection designed specifically to stop paintballs and meeting ASTM standard F1776 ( USA) or CE standard (Europe) must be worn by user and any person within range.
TM Confirm number entry using the external GREEN button. 2---- Confirm number entry using the external GREEN button. s s Confirm full PIN number entry using the external RED button. PINSt 24680 s s Scroll through 5th flashing digit using the external ORANGE button. 2468- 24680 0---- Go to point 1. Clear display to start again. Scroll through 4th flashing digit using the external ORANGE button. s s Scroll through 3rd flashing digit using the external ORANGE button.
Hold trigger A---- ----- TEXT SAFE contents important safety guidelines Press button twice Scroll through to 1st character or number. External ORANGE button. s s operating instructions s s Hold trigger external LCD menus whilst in SAFE external LCD C.O.P.S. menu whilst LIVE Hold trigger internal tournament LCD menus s Confirm character entry. External GREEN button. Confirm character entry. External GREEN button. s s Hold trigger ANG-- Scroll through to 2nd character.
C.O.P.S. SENSOR SOCKET BUTTON (SWITCH 5) •INTERNAL MENU • RESET DEFAULT 14-WAY VALVE SOCKET BUTTON (SWITCH 6) •INTERNAL SUB MENU • RESET DEFAULT HOPPER SOCKET BATTERY SOCKET CHARGER SOCKET RED BUTTON (SWITCH 2) • EXTERNAL ON/OFF • C.O.P.S. MENU GREEN BUTTON (SWITCH 4) • EXTERNAL SUB MENU • TIMER ARM/STOP • PIN ENTER • C.O.P.S. MENU ORANGE BUTTON (SWITCH 3) • EXTERNAL MAIN MENU • PIN SELECT • C.O.P.S. MENU 14-WAY VALVE TO HOPPER MOTOR TEST POINT HOPPER CONVERSION KIT SIGHT RAIL C.O.P.S.
contents important safety guidelines operating instructions external LCD menus whilst in SAFE external LCD C.O.P.S. menu whilst LIVE internal tournament LCD menus figures maintenance fault finding tables useful conversions warranties update info TM your ANGEL iR3TM ANGEL iR3 26 figures – general assembly BOLT LPR PRESSURE TESTER.
TM M2.5 x 12mm SIGHT RAIL CSK M3 x 6mm GRUB M5 x 8mm BACK PLATE CLAMP PLATE BREECH BLOCK LOCK PIN 14-WAY VALVE BREECH BLOCK PULL KNOB BREECH BLOCK SPRING VALVE MANIFOLD MANIFOLD GASKET TOGGLE SWITCH HAMMER SNAP ‘O’ RING SNAP RING SCREW TM C.O.P.S.
contents important safety guidelines operating instructions external LCD menus whilst in SAFE external LCD C.O.P.S.
TM • Always wear industrial standard eye protection when performing any maintenance on the ANGEL iR3TM . GENERAL CARE AND CLEANING ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES Ensure a barrel blocking device is fitted to the ANGEL iR3TM Ensure the hopper is removed from the ANGEL iR3TM Ensure that there are no paintballs in the ANGEL iR3TM Always remove the first stage regulator and relieve all residual gas pressure from the ANGEL iR3TM before disassembly.
maintenance The low-pressure regulator controls the pneumatic cycle of the ANGEL iR3TM and is located in the lefthand chamber at the front of the ANGEL iR3TM body. The pressure needs to be at 95 psi (6.6) output at a pressure of 500 psi at the second stage regulator. LPR adjustment is achieved by the removal of shims. Each shim equals approximately 3.5 PSI/0.2 BAR. We recommend the use of the optional service tools and lubrication of parts with LOVE JUICE EXTREME GREASE only (see general assembly diagram).
TM Ensure a barrel blocking device is fitted to the ANGEL iR3TM Ensure the hopper is removed from the ANGEL iR3TM Ensure that there are no paintballs in the ANGEL iR3TM Always remove the first stage regulator and relieve all residual gas pressure from the ANGEL iR3TM before disassembly. • The ANGEL iR3TM can hold a small residual charge of gas, typically 2 shots, with the first stage regulator removed. Always discharge the marker in a safe direction to relieve this residual gas pressure.
maintenance • Retract breech block lock pin and spring. • Using circlip pliers or the ram location tool (optional accessory) rotate ram assembly clockwise until slight resistance is felt in opening the breech block. If rotated too far the breech will not open so rotate counterclockwise and repeat operation. Note: The ram must always be rotated clockwise when setting. • Replace the breech block lock pin, spring, back plate and breech block pull knob. CAUTION: Ensure that no wires become trapped.
• • • • • • TM Ensure the ANGEL iR3TM is degassed and switched off via the isolating switch on the rear of the marker. Remove the left-hand side grip cheek cover by removing the 3 screws using a suitable metric Allen key. Unplug the battery and solenoid plugs. Remove the 2 grip frame screws holding the frame to the body using a suitable metric Allen key. Remove the frame from the body. Remove the trigger return spring from the top of the trigger.
maintenance TESTING PNEUMATICS/ELECTRONICS ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY INSTRUCTIONS AND GUIDELINES • • • • The ANGEL iR3TM is live and capable of discharging. Ensure a barrel blocking device is fitted to the ANGEL iR3TM Ensure the hopper is removed from the ANGEL iR3TM Ensure that there are no paintballs in the ANGEL iR3TM The design of the ANGEL iR3TM can be divided into two elements, which enable you to evaluate where a problem may have occurred.
TM IS THERE AIR OR NITROGEN PRESENT See gassing up the ANGEL iR3TM. IS THE BATTERY PACK CHARGED? See charging the ANGEL iR3TM. THE BATTERY ISN’T CHARGING. Check vehicle voltage. IS THE ANGEL IN ‘SAFE’? See switching the ANGEL iR3TM On. IS THE ISOLATOR SWITCHED OFF? See switching the ANGEL iR3TM On. IS THE TRIGGER NOT CLOSING THE SWITCH? See trigger adjustment. IS THE TRIGGER NOT RELEASING THE SWITCH? See trigger adjustment. IS THE BOLT JAMMED FORWARD? Clear blockage from breech.
PRESSURE 1 atm = 1.01325 bar 1 atm = 14.6959 psi 1 bar = 14.5038 psi 1 psi = 0.0689476 bar VELOCITY 1 Ft/s = 0.3048 m/s 1 Ft/s = 0.6818180 Mph 1 m/s = 3.28084 Ft/s 1 m/s = 2.23694 Mph 1 m/s = 3.6 Kph MASS 1g = 0.05274 oz 1 Kg = 2.20462 Ib 1 oz = 0.0283495 Kg DISTANCE 1 mm = 0.0393701 Inch 1 Inch = 25.4mm 1 thou = 25.4 micron 1 micron = 0.0393701thou FORMULA TO CONVERT FEET PER SECOND (Ft/s) TO FOOT Ibs (Force) 1 foot Ibs (force ) = 1.35582 Joules 1 Joule = 0.
TM WDP Ltd gives this warranty subject to the following conditions: • Proof of purchase is required in all warranty claims. • Warranty is not transferable. • The company shall be under no liability in respect of any defect arising from fair wear and tear. • Seals, batteries, wiring, circuit boards, LCD displays and exhaust valves are not covered by this warranty.
terms of warranty The supply and purchase of the ANGEL iR3TM is subject to the company’s standard terms and conditions of sale, a copy of which is available on request. ANGEL iR3TM patents applied for, design rights and all rights reserved. The ANGEL iR3TM is marketed and distributed by WDP Ltda company registered in England No. 2114341. No warranty is given to parts not manufactured by the Manufacturer and all liability for loss damage or injury is excluded.
TM 6. User’s Responsibility for Safety and Indemnification It is Buyer’s or other user’s responsibility to obtain all training and means that may be necessary to effectively protect all individuals and property from damage and bodily injury, which otherwise may result from the use or maintenance of the Product, and to use the Product in accordance with operating instructions and due care.