User's Manual

contents
important safety
guidelines
operating instructions
external LCD menus
whilst in SAFE
external LCD C.O.P.S.
menu whilst LIVE
internal tournament
LCD menus
figures
maintenance
fault finding tables
useful conversions
warranties
update info
your ANGEL iR3
TM
11
ANGEL iR3
TM
external LCD menus whilst in SAFE
CMROF feature (maximum rate of fire limit with C.O.P.S.
TM
option ON)
This allows you to tune your maximum rate of fire to your style of play and feed system when the
C.O.P.S.
TM
option is selected. Certain modes are capped or non-adjustable. The rate of fire should not be
set greater than your feed system is capable of delivering. This cannot be changed by the external menu
(See internal menu diagram fig.6 p21). See table on Modes for maximum allowable settings (p 21).
Game timer with 3 interactive alarms (fig.2 page 13)
The “vibes” timer incorporates 3 independent alarms that take the stress out of game play. It will
also allow you to play set moves in unison with your team mates. The timer can be set in 30 second
increments from 0 to 30 minutes. The timer is started with your first shot, which allows you to
concentrate on your game play. The 3 alarms can be individually set in 30 second increments.
(See internal menu diagram fig.3 p 14-15)
Vibes game alarm feature (fig.3 page 14-15)
This feature allows you to switch the vibrator alarm ON or OFF. The vibes alarm is independent of the
game timer functions. (See external menu diagrams for setting.)
Dwell feature (fig.3 page 14-15)
Dwell controls the valve opening time. Longer dwell uses more gas and generates more noise but allows
the marker a greater tolerance to paint, temperature and pressure variables. Shorter dwell uses less gas
and reduces noise, but is less tolerant of poor quality paint.
CAUTION:
Adjustment is only recommended if you wish to fine-tune your marker to specific accessories.
Mode feature
• In certain countries local applicable laws or industry standards may mean certain modes may not
be enabled or allowed. Check with law enforcement office, or local professional paintball venue.
The current mode selected will be displayed. 26 modes of shooting may be selected, including 5 modes
that you may program yourself using the ANGEL INFRA RED LINK. (See Internal Tournament LCD
adjustments and diagrams for setting.)
Battery Status feature
The battery status is indicated at all times by the 4-segment display. Power is drawn whilst the ANGEL
iR3
TM
has power connected. A battery will last approximately 280 hours until it is discharged. To prevent
this discharge ensure the isolator switch is in the OFF position at the end of the day or event. The last
segment indicates that you have approximately 16,000 shots left with a hopper being powered.
Hopper T (Timer)
This allows the user to set the duration that the hopper motor is activated for.
It can be set between 0.1- 2.0 seconds.
ADHERE STRICTLY TO THESE AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES