User's Manual

7
TESTING THE SOUND FUNCTION
Switch the Nursery Unit to "Sound Only"
. Turn the Parents Unit ON and select either channel A, B or C. Make
sure it is set to the same channel as the Nursery Unit. The green power indicator LED will light up. Choose the
channel that gives you the best reception.
Test the sound: have someone else speak into the Nursery Unit or place a radio near the Nursery Unit. You
should hear sound from the Parents Unit. If there is no sound, refer to the Troubleshooting section.
Adjust the volume to the desired level using the slide button on the right of the Parents Unit.
TESTING THE BATTERY POWER
Verify that the units are operating on battery power by installing 3 AAA NiHM rechargeable batteries (included)
in the Parents Unit and 4 regular AAA batteries (included) in the Nursery Unit and unplugging the AC adapters.
The green Power Indicator should light up on all units.
Movement Sensitivity Adjustment
The movement sensitivity adjustment dial has been preset to a level which will suit most situa-
tions. The highest sensitivity level is 5 (most sensitive) and the lowest sensitivity level is 1 (least
sensitive).
You may get false alarms if your baby is in a very deep sleep or has moved to the edge of the crib. If you get
false alarms due to these circumstances, you should increase the sensitivity level by using the sensitivity dial
on the back of the Nursery Unit.
NOTE: Adjust the sensitivity level if you receive false alarms and you have followed the advice in the
Troubleshooting section for false alarms. Make a note of the position of the sensitivity dial before you change
it should you wish to return to that setting.
To increase the sensitivity level, start by increasing it by half a level. For example, if the level is currently at
2.5, increase it to 3. Use the monitor as you normally would. If you still experience false alarms, increase it by
another half level. If you are still experiencing false alarms when you have reached level 5, please consult our
customer service link on our website at www.angelcare-monitor.com
Because the Sensor Pad may detect movement from many sources from both inside and outside your baby’s
room, be sure all vibration sources are eliminated before changing the movement sensitivity level. Check to
see if the Sensor Pad is resting on a flat, firm surface. Place the crib near a solid supporting wall and away
from strong air currents. Do not use crib mobiles or accessories that may cause vibrations. Avoid contact with
the crib when monitor is in use.
To make sure you have avoided all external sources of vibration, take your baby out of the crib while the mon-
itor is on. If the alarm does not sound after you take your baby out of the crib, the sensitivity level may need
to be decreased. To decrease the sensitivity level, adjust by half a level by going from 2.5 to 2. If you are still
experiencing this problem when the level is set to 1, please consult our customer service link on our website
at www.angelcare-monitor.com
Movement Sensitivity adjustment