User Manual

ES
CAN
DE
US
IT
3299702_rev.2.fIDM
English
-
53
-
Use and installation manual
The electrical connection is carried out from the rear part.
The electrical mains cables must be correctly sized and
selected based on the installation conditions.
The blast chiller have a junction box to allow the
conductors fitting.
The grounding cable is to be directly connected to a good
grounding system.
The guarantee will cease and the Manufacturer will not
be liable for any damage to appliances or operators aris-
ing from the non-compliance with the and tamperings to
any part of the appliance (electric, thermodynamic or hy-
draulic plant).
The equipment has a condensation collection tray. The tray is extractable from the
lower part of the equipment.
Should the appliance have been transported horizontally instead of a vertical position
DO NOT START THE APPLIANCE IMMEDIATELY. WAIT FOR AT LEAST 24
HOURS BEFORE OPERATING.
The manufacturer declines any responsibility and any warranty obligation if
damage occurs to the equipment imputable to transportation in a horizontal po-
sition.
Carry out the following checkings:
1–Outside temperatures must be included between 59°F and 100°F.
2–Turn on the appliance and wait 30 minutes before the use if the external tempera-
ture is “low”.
3–Check power input
4–Carry out at least one full quick cooling cycle
The following information concerns skilled staff only.
Door micro-switch: Prevents the appliance from working when the door is open
Overall protection fuses: Protect the whole power circuit from and short-circuits and
overloads
Compressor thermal relay: Operates in case of an overload or working failures
Motor-fan thermal relay: Operates in case of an overload or working failures
Safety pressure-switch: Operates in case of coolant over-pressure
Cabinet temperature control: Is run by NTC probe through the relevant electronic
card
Core temperature control: Is run by PT100 probe through an electronic card
Electronic boards: based on the parameters entered they command and control any
devices connected to the equipment.
CONDENSATE DRAIN
TESTING
CONTROL AND SAFETY SYSTEMS