User Manual
Troubleshooting
Potential Incorrect Use and Fault Conditions:
Problem
The platter doesn’t turn
although the unit is
switched on
No signal through one or other
channel or both channels:
Strong hum on phono input:
Distorted of inconsistent sound
from one or both channels:
Solution
These turntables are manufactured to the highest standards and undergo strict quality controls before leaving the factory.
Faults that may possibly occur are not necessarily due to material or production faults but can sometimes be caused by
incorrect use or unfortunate circumstances. Therefore the following list of common fault symptoms is included.
- The unit is not connected to the main power supply.
- No power at the outlet.
- Drive belt is not installed or has slipped off.
- The unit automatically switched in standby mode, power OFF and ON again on
the backside.
- Phone input not selected at the amplifier.
- Amplifier not switched on.
- Amplifier or speakers muted.
- No connection to the speakers.
- No connection between turntable and amplifier.
- Wire leads not connected to the cartridge.
- No ground connection from the cartridge, arm, or arm cable to amplifier or
ground loop.
- Turntable too close to speakers.
- Turntable is connected to the wrong input of the amplifier.
- Needle or cantilever damaged.
- Drive belt overstretched or dirty.
- Platter bearing without oil, dirty or damaged.
- Dust on the stylus.
- MM/MC switch on the pre-amplifier set incorrectly.