User Manual

1. Disconnect unit from power supply.
2. Allow light to cool to room temperature before handling.
3. Remove safety glass by unscrewing the three retaining screws.
4. Remove expired lamp by pulling it straight out of the socket.
5. Insert new lamp in its plastic sleeve by pushing pins straight into the socket (a very
tight fit is normal and necessary for proper operation). Then remove plastic sleeve.
6. Replace safety glass.
Caution: Never handle quartz bulbs with bare fingers, as skin oils can cause the bulbs to
shatter unexpectedly. Always use cotton gloves or a clean fabric swatch.
Replacement Quartz Halogen Lamps: 300W 2-pin JCD 120V
Changing the lamp
7