4. FIRST TIME USE
The instructions given in chapter 3-INSTALLATION must be carried out before the new appliance can be put into
operation. This appliance may only be used in combination with the supplied coffee containers and synthetic
filters.
- When used for the first time the appliance works according to the standard factory settings.
The various settings can be altered by trained, authorized personnel. See chapter 11-OPERATOR MENU.
- This chapter will explain the coffee brewing and hot water system process:
when the appliance is used for the first time.
when the appliance has not been used for more than 1 week, for example after a holiday period.
4.1 Flushing the flow heater system
1. Open the water tap and check if the swivel connections are not leaking.
2. Put the cable with inlet plug into the back of the container and insert the plug into the socket of the
flow water heater (fig. 1-1).
3. Check if the containers are positioned correctly, with a filter unit (still without coffee), and position the
swivel arm above the centre of the filter.
4. Switch the appliance on by putting the ON/OFF switch (fig. 1-2) in position I, the display (fig. 1-6.3)
lights up and you will hear a beeping sound. Then the display will indicate the standard choices.
5. Press selection button 2 (fig. 1-6.5) and confirm your choice by pressing the START button (fig. 1-6.8).
The coffee system starts filling and the brewing process starts. In the display appears the text: BREWING.
With the STOP button (fig.1-6.2) the brewing process can be interrupted at any moment. When the water
supply stops coming out of the swivel arm, you will hear a beeping sound (1x short). In the display appears
the text: LEAKING. The leaking time is set as standard to approx. 5 minutes, and its ending is indicated by
a beeping sound (3x short).
6. Empty the container with the drainage tap.
7. Position the swivel arm above the other filter and follow the above procedure once again if the model is
equipped with two containers.
8. Once the container is empty the coffee maker is ready for use.
4.2 Flushing the boiler system
Switch on temperature indication in display See 12.5.2 Show temperature (menu 4.1)
Change temperature See 12.5.3 Temperature (menu 4.2)
Switch on the continuous heating function 97+ See 12.5.3.1 Switch on the continuous heating function 97°C+
1. Press the hot water system on/off button (fig. 1-7.1). The hot water system fills itself automatically,
and then heats up. A flashing tap symbol appears in the display.
2. The tap symbol stops flashing when the hot water system is hot enough (90°C).
The hot water system can be switched off at any moment by pressing the on/off button again (fig. 1-6.1).
The tap symbol disappears from the display and the system will no longer refill or heat up.
3. Draw off approx. 2 litres of water using the no-drip tap (fig. 1-3) and throw it away.
The hot water system fills itself automatically with fresh water.
4. The boiler system is now ready for use.
WARNING
The hot water system steam outlet can be found on the top of the tower.
Steam can escape through this opening during normal heating and heating
with the continuous heating function (97°C+) switched on! Do not touch the
moisture outlet. There is a danger of burning.