QR code for user manual Version 1.
Ambiane SP16 Recessed Table of contents 1. Attention ..................................................................................................................................................................... 3 2. Fixture exterior view ................................................................................................................................................... 4 3. Installation ...................................................................................................
Ambiane SP16 Recessed 1. Attention The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. The unit was designed for indoor use only. Do not install the unit near highly inflammable liquids or materials. Do not allow anything to rest on the unit. Do not install the unit near an open flame. Do not install the unit in dirty, dusty or badly ventilated location.
Ambiane SP16 Recessed 2.
Ambiane SP16 Recessed 3. Installation The Ambiane SP16 must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations. Always switch off power supply of the control unit before connecting or disconnecting the control unit or the LED unit. The lower ceiling (or another structure) intended for installation of the Ambiane(s) SP16 must safely hold at least 5 times weight of the Ambiane(s) SP16 placed on it. 1.
Ambiane SP16 Recessed Fasten the top part of the yoke (11) on the ceiling or another structure by means of three openings in the yoke. 3. Fasten the control unit (1) on the ceiling by means of two holes in the housing of the control unit. 4. Install the terminal block (2) on the LED unit cable. 5. Install the terminal block (3) on the DMX cable and connect it to the PCB RB 3729 of the control unit (1). 6.
Ambiane SP16 Recessed Example of connection: The green LED on the PCB signals way of DMX address setting: LED lights-DMX address is set by means of the DIP switch. LED does not light- DMX address is set by means of RDM. The DIP switch (6) is accessible by the aperture (5) in the cover of the control unit (1).
Ambiane SP16 Recessed Primary power connection Connector Vcc 0V Function Power + Power - Connector Vcc 0V Function Power + Power - Secondary power connection DMX connection Connector D+ D- 0V Function Data + Data- Data ground (shielding) Connector D+ 0V Function +10V 0V 0-10V connection DMX connectors are used for 0-10V control Primary and secondary power. The primary power input serves for a standard power (e.g. Ambiane Power AP).
Ambiane SP16 Recessed 9. After connecting needed cables to the control unit, press both spring clips (8) upwards and insert the LED unit (9) into prepared hole in the lower ceiling (10). The LED unit will stay fixed in desired position by means of the two springs. Connect the terminal block on the LED unit cable to the control unit.
Ambiane SP16 Recessed 10. If you install Ambiane SP16 Recessed with yoke. After connecting needed cables to the control unit, insert the LED unit (9) into prepared hole in the lower ceiling (10) and screw the bottom part of the yoke (13) to the top part of the yoke (11) by means of two screws (12) with washers. Connect the terminal block on the LED unit cable to the control unit.
Ambiane SP16 Recessed 3.1. DMX and DALI address setting and control The DIP switch on the control PCB (RB3729) allows you to set DMX address and run a test light. DIP 10 - if it is switched to ON=test light (the fixture lights at 3200K (for RGBW and TW version)). DIP 11 - has to be switched to OFF position to receive DMX 512 and DALI, position ON=0-10V control.
Ambiane SP16 Recessed DALI control Addressing of the fixture has to be made by means of an external DALI controller. If you need to start the permanent DALI control of the fixture (fixture will not respond to DMX commands), the external DALI controller has to send activating command (8=ON). If you need to stop the permanent DALI control of the fixture, the external DALI controller has to send deactivating command (0=OFF). 3.2 0-10V control DIP 11 has to be set in ON position.
Ambiane SP16 Recessed SENSOR_DEFINITION * SLOT_INFO * SLOT_DESCRIPTION * DEFAULT_SLOT_VALUE * PARAMETER_DESCRIPTION * 5. DMX protocols Variant RGBW, version 1.
Ambiane SP16 Recessed Variant TW, version 1.1 Mode 1 Mode 2 Mode 3 Mode 4 DMX Channel Channel Channel Channel value 1 1 0-255 1 1 0-255 2 2 0-255 2 3 2 3 0-255 3 4 0-255 Variant TD, PW version 1.
Ambiane SP16 Recessed 6. Technical specifications Nominal input voltage: Input voltage range: Max. power consumption: Light source: CRI: Beam angle: Projected lumen maintenance: Colour variants: Colour temperature of white: Control: Settings/Addressing: DMX channels (RGBW variant): DMX channels (TW variant): DMX channels (TD, PW variant): Power supply: Operating ambient temp.
Ambiane SP16 Recessed Dimensions (spring clips version) mm [inch] 16
Ambiane SP16 Recessed Dimensions (yoke version) mm [inch] 17
Ambiane SP16 Recessed Dimensions (Control unit) mm [inch] Included items 1 x Ambiane SP16 Recessed 1 x Control unit 1 x Set of cable connectors 1 x User manual Optional items Ambiane Power AP (P/N 10063994) Ambiane Power Rack (P/N 10063873), Ambiane Power Rack US (P/N 10063951) 18
Ambiane SP16 Recessed 7. Cleaning and maintenance Disconnect from the mains before starting any maintenance work Keep the fixture clean, especially light source and the ribbed heat sink. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts. 7.1 Software update The fixture has to be connected to power during software update.
Ambiane SP16 Recessed The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via the Robe Universal Interface/Robe Universal Interface WTX and a USB cable connected to the control PC with the Robe Uploader running. The fixtures have to be connected to power. The control PC should be connected to the Internet. The Robe Uploader software and user manual is available at https://www.robe.
Ambiane SP16 Recessed 8. ChangeLog This section summarizes changes in the user manual. Version of manual Date of issue Description of changes 1.0 Version with yoke added 23/11/2022 Specifications are subject to change without notice November 23, 2022 Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o.