User Manual

Ambiane SP16 Recessed
11
3.1. DMX and DALI address setting and control
The DIP switch on the control PCB (RB3729) allows you to set DMX address and run a test light.
DIP 10 - if it is switched to ON=test light (the fixture lights at 3200K (for RGBW and TW version)).
DIP 11 - has to be switched to OFF position to receive DMX 512 and DALI, position ON=0-10V control.
Note: If DIP 11=OFF (fixture is controlled by DMX and DALI), the last coming command switches the fixture to the
corresponding operation mode (DMX operation by a DMX command, DALI operation by a DALI command). E.g. the
fixture stays in a DALI operation and last coming command is a DMX command which switches the fixture to DMX
operation. Next command is a DALI command and switches the fixture to the DALI operation etc.
If you need the permanent DALI operation, you have to send a DALI command 8 to the fixture.
DMX control
The DMX start address, is the first channel used to receive instructions from the DMX controller. The address may
be any channel from 1 to 512. DMX address can be set either by DIP switch or by RDM. DMX address set by RDM
overwrites address set by DIP switch and vice versa. The green LED on PCB signals way of DMX address setting:
LED lights-DMX address is set by means of the DIP switch.
LED does not light-DMX address is set by means of RDM.
The DIP 11 has to be set to OFF position.
Example of DMX addresses: