User Manual
Ambiane SP16 Recessed
8
Primary power connection
Connector
Vcc
0V
Function
Power +
Power
-
Secondary power connection
Connector
Vcc
0V
Function
Power +
Power
-
DMX connection
Connector
D+
D
-
0V
Function
Data +
Data
-
Data ground
(shielding)
0-10V connection
Connector
D+
0V
Function
+10V
0V
DMX connectors are used for 0-10V control
Primary and secondary power.
The primary power input serves for a standard power (e.g. Ambiane Power AP).
The secondary power input serves for a backup power (in case that primary power failed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled. In
case of primary power loss, the secondary power is enabled.
If the fixture is supplied via the secondary power, the light output of the fixture is a white colour 3200K (RGBW, TW
version) and its light intensity can be set by a trimmer (7).
8. Set the DIP switch (6) according to your operation mode. This DIP switch is accessible by aperture (5) in the
cover of the control unit (1). Please see the chapter 3.1 DMX and DALI address setting and control.
The fixture can be controlled by one of the following methods: DMX 512
DALI
0-10V (PW or TD version only)
The fixture is equipped with two DMX and DALI connection blocks (on the PCB RB 3729) for easy connection to a
DMX or DALI chain (In/Out method).