QR code for user manual Version 1.
Eminere Inground Wireless DMX Table of contents 1. Safety instructions ......................................................................................................................................................3 2. Fixture exterior view ................................................................................................................................................... 4 3. Installation .................................................................................................
Eminere Inground Wireless DMX FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
Eminere Inground Wireless DMX Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g.
Eminere Inground Wireless DMX 3.1 Mounting the Eminere Inground Warning! If the Eminere Inground will be exposed to max. allowed static load, the subsoil under the installation sleeve has to withstand load of: 45kN (standard covering glass) 23kN (antiskid covering glass). Example of installation of the Eminere Inground 2 1. Prepare an adequate hole with a good drainage leaving at least 300 mm of gravel on the bottom of the hole for inserting the mounting sleeve (1) into the prepared hole.
Eminere Inground Wireless DMX The supply cable to the mounting sleeve and power/data cable from the mounting sleeve must be placed in a protective tube (12). 6. After connecting cables to the junction box (8), screw the Eminere Inground (13) to the mounting sleeve (1) by means of the four countersunk- allen head bolts M5x25 (14). The screws (14) must be tightened smoothly with torque of 4Nm. Do not use impact wrench. 7.
Eminere Inground Wireless DMX Junnction box The Eminere Inground is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC power source from 120-277 Volts. Do not connect (disconnect) Emineres Inground each other when they are under voltage! 1. Unscrew the four screws M4x20 (17) on the cover of the junction box and remove this cover (18) with gasket (19) to get access to the connection block (20). 2. Connect cables to the connection block (20).
Eminere Inground Wireless DMX Cable gland M20: We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body in case that you need to unscrew and remove the cable gland from the housing of the junction box and and screw it back to the housing. Remove end caps from cable glands before passing cables into the junction box.
Eminere Inground Wireless DMX Junction box filled with resin. Earth wire 4. Screw the cover (18) with gasket (19) to the junction box by means of the four screws (17) and check they are fully tighten. 8. If you install two or more Emineres Inground side by side, you have to screw three types of the cover plates: end (15), middle (23) and continuous (22).
Eminere Inground Wireless DMX Cover plates overview: Single fixture End fixture in a row of fixtures Middle fixture in a row of fixtures (15)-Cover plate end (optional ) (22)-Cover plate continuous (optional) (23)-Cover plate middle (one piece is a standard part of fixture) 9. Tilt adjustment. The Eminere Inground can be tilted by +/-15° after installing it in the mounting sleeve. Push and hold the small tube (24) to release the lock of the Eminere Inground and tilt the device to desired position.
Eminere Inground Wireless DMX DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager. Direct visibility between a transmitter and the Eminere Inground Wireless DMX must be ensured without no obstacles (bildings, trees, cars....). The angle between the ground with the Eminere Inground Wireless DMX and the transmitter´s antenna has to be more than 10°.
Eminere Inground Wireless DMX DMX addressing of connected Emineres Inground has to be done manually by means of the Robe Universal Interface WTX and the software RDM Manager. Theoretically up to 32 Emineres Inground can be connected in DMX chain, but number of connected Emineres Inground in series also depends on their cable length, power voltage and type of Emineres Inground. The tables below state max. theoretical number of Emineres connected in series without Booster boxes.
Eminere Inground Wireless DMX 4.
Eminere Inground Wireless DMX Max. static load • Standard tempered glass: 45kN • Antiskid tempered glass: 23kN Operating ambient temperature range • -20°C /+40°C (-4°F /+104°F) Operating temperature • +80 °C @ Ambient +40 °C (+176 °F @ Ambient +104 °F) Connection • Junction box Weight • Eminere Inground 2: 23.6 kg / 52 lbs (12.2 kg / 26.9 lbs Eminere Inground 2 Fixture, 11.4 kg / 25 lbs install. Sleeve) • Eminere Inground 4: 43.85 kg/ 96.67 lbs (22.65 kg / 49.93 lbs Eminere Inground 4 Fixture, 21.
Eminere Inground Wireless DMX Dimensions with mounting sleeve (All dimensions in mm [inch]) • Eminere Inground 2/Eminere Inground 4 Included items • 1 x Eminere Inground • 1 x mounting sleeve • 1 x User manual Optional accessories P/N 10980506 Eminere Inground 2 Mounting Sleeve P/N 10980508 Eminere Inground 2 cover plate continuous P/N 10980539 Eminere Inground 4 Mounting Sleeve P/N 10980526 Eminere Inground 4 cover plate continuous P/N 10980509 Eminere Inground cover plate end P/N 13053138 Cable CE WCA P/
Eminere Inground Wireless DMX 5.1 Disposing of the product To preserve the environment please dispose or recycle this product at the end of its life according to the local regulations and codes. 6. ChangeLog This section summarizes changes in the user manual. Version of the manual Date of issue Description of changes 1.1 08/09/2021 Option Wireless DMX to wired DMX removed 1.2 19/10/2021 Technical specifications changed 1.3 26/11/2021 Optional accessories changed 1.