NETWORK ANALYZERS Vector Network Measurement Systems . . . . . . . . 350 Vector Network Measurement System/Direct-Access Receiver . . . . . . . . . . . . . 356 Power Amplifier Test System (PATS) . . . . . . . . . . . 358 Vector Network Analyzers . . . . . . . . . . . . . . . . . . . 360 Millimeter Wave Vector Network Analyzer . . . . . . . 365 Broadband Vector Network Analyzer . . . . . . . . . . . 368 Vector Network Analyzer Automatic Calibrator . . . . 370 VNA and VNMS Calibration Kits . . . . . . . . .
NETWORK ANALYZERS VECTOR NETWORK MEASUREMENT SYSTEMS MS4622A/B, MS4623A/B 10 MHz to 3 GHz 10 MHz to 6 GHz Innovative Manufacturing Solutions for Measuring S-Parameters, NF, P1dB, IMD, and 3-Port Devices GPIB Anritsu has a new family of RF Vector Network Measurement Systems, the MS462XA and MS462XB. Code named Scorpion®, the MS462XX line is much more capable than traditional VNAs.
NETWORK ANALYZERS Performance and functions • Vector error-corrected noise figure measurements The MS4622B and MS4623B Vector Network Measurement Systems deliver the industry’s first ever capability for making vector error-corrected noise figure measurements on active devices in today’s hottest market – wireless communications.
NETWORK ANALYZERS Test port characteristics Specifications Standard connector type N female Optional connector types 3.5 mm female, 3.5 mm male, GPC-7, N male Measurement port characteristics Source specifications Directivity (dB) Source match (dB) Load match (dB) 3.
Receiver specs NETWORK ANALYZERS Average noise level –100 dBm in 10 Hz IF Bandwidth (< 3 GHz); Typically > –110 dBm in narrowband sweep –90 dBm in 10 Hz IF Bandwidth (> 3 GHz); Typically > –100 dBm in narrowband sweep Maximum input level +27 dBm, +20 dBm noise figure mode Damage level > +30 dBm, > +23 dBm noise figure mode Measurement times are measured using a single trace (S21) display and one average.
Display capabilities NETWORK ANALYZERS Display channels Four, each of which can display any S-parameter or user-defined parameter in any format with up to two traces per channel for a maximum of eight traces simultaneously. Each channel is also capable of displaying harmonics, noise figure, intermodulation distortion, or time domain trace. A single channel, two channels (1 and 3, or 2 and 4), or all four channels can be displayed simultaneously.
General Power requirements 85-240 V, 48-63 Hz, 540 VA maximum Dimensions 222H x 425W x 450D mm (8.75 x 16.75 x 17.75 in) Weight 16 kg (35 lb) Environmental NETWORK ANALYZERS Storage temperature range –40°C to +75°C. Operating temperature range 0°C to +50°C (specifications apply at 23°C ±3 °C). Relative humidity 5% to 95% at +40°C.
NETWORK ANALYZERS VECTOR NETWORK MEASUREMENT SYSTEM / DIRECT-ACCESS RECEIVER MS4622C, MS4623C 10 MHZ to 3 GHz 10 MHz to 6 GHz For Measuring Antennas, Frequency Conversion, and Multiple-Output Devices GPIB The MS462XC series of RF vector network analyzers are configured as direct-access receivers for antenna, frequency conversion, and multiple output device measurements.
NETWORK ANALYZERS Specifications Ordering information General measurement and enhancement display capabilities are the same as those for the MS4622A/B, MS4623A/B. Please specify model/order number, name, and quantity when ordering. Number of channels Four measurement channels Operating port power (A1, A2, B1 and B2) –5 dBm for 0.
NETWORK ANALYZERS POWER AMPLIFIER TEST SYSTEM (PATS) ME7840A 800 to 2400 MHz, 100 Watts Easy-to-Use System for Power Amplifier Design and Manufacturing GPIB PATS is a flexible, easy-to-use system for power amplifier design and manufacturing. It allows real-time, simultaneous tuning of various amplifier parameters, including IMD and hot S22 in both swept-frequency and swept-power modes.
NETWORK ANALYZERS PATS Software Results With frequency sweeps as fast as 150 µs/point and power sweeps as fast as 150 µs/point, you can quickly, thoroughly, and accurately characterize your power amplifiers in real-time. Simultaneously overlay measurements in both frequency and power and see the results of over 250 datapoints updated twice per second. Ordering information Please specify model/order number, name, and quantity when ordering.
NETWORK ANALYZERS VECTOR NETWORK ANALYZERS 37100C, 37200C, 37300C Series 22.5 MHz to 65 GHz For Fast and Accurate S-Parameter Measurements GPIB The 37200C and 37300C series microwave vector network analyzers (VNAs) are high performance tools designed to make fast and accurate S-parameter measurements across the 22.5 MHz to 65 GHz range. These network analyzers integrate a synthesized source, S-parameter test set, and tuned receiver into a single compact package that is ideal for benchtop testing.
NETWORK ANALYZERS dynamic range and resolution. The exclusive phasor impulse mode will show you the true impedance characteristics of mismatches in waveguide, microstrip, and other band-limited media. • Multiple source control Conveniently test mixers and multipliers through the 37100C/ 37200C/37300C's multiple source control. Separately control the frequency of two sources and a receiver without the need for an external controller.
NETWORK ANALYZERS Specifications Number of channels Four measurement channels Parameters S11, S21, S12, S22; or user defined, complex input and output impedance; complex input or output admittance; complex forward and reverse transmission Domains Formats Data points Measurement capabilities Reference delay Can be entered in time or in distance. Automatic reference delay adds the correct electrical length compensation at the push of a button.
NETWORK ANALYZERS Table 1a Dynamic range (37100C) Model Frequency (GHz) Max. signal into ax, bx (dBm) Noise floor (dBm) Receiver dynamic range (dB) Source power (dBm, typical) 37147C 0.0225 2 20 –18 –12 –12 –122 –106 –103 104 94 91 10 8 5 37169C 0.0225 2 20 40 –18 –12 –12 –15 –122 –106 –103 –100 104 94 91 85 10 8 3 –3 Table 1b Dynamic range (37200C/37300C) Model 37217C 37225C 37247C 37269C 37277C 37297C 37317C 37325C 37347C 37369C 37377C 37397C Frequency (GHz) 0.0225 2 8.6 0.
NETWORK ANALYZERS Table 2 Power range Model Rated power (dBm) Minimum power (dBm) 37147C +5 –15 37169C –3 –23 0 –20 37269C –15 –27 37277C –7 –27 37297C –7 –19 37317C 0 –95 +5 –90 Resolution (dB) 37217C 37225C 37247C 37325C 37347C 37369C –7 –97 37377C –7 –87 37397C –7 –79 0.05 Ordering information Please specify model/order number, name, and quantity when ordering. Model/Order No.
NETWORK ANALYZERS MILLIMETER WAVE VECTOR NETWORK ANALYZER 37000 Family 33 to 140 GHz High Performance Millimeter Wave Vector Network Analysis GPIB 7 The 37000 family millimeter wave vector network analyzer (VNA) extends the exceptional performance of the Lightning VNA family to 140 GHz.
NETWORK ANALYZERS Specifications • System performance Waveguide designation Q-Band (WR-22) V-Band (WR-15) E-Band (WR-12) Extended E-Band W-Band (WR-10) Extended W-Band F-Band (WR-8) Frequency range (GHz) 33 to 50 50 to 75 60 to 90 56 to 60 60 to 85 85 to 94 75 to 100 100 to 110 65 to 75 75 to 100 100 to 110 90 to 115 115 to 140 Maximum signal into port 2 (dBm) +10 +8 +8 +8 +6 +6 +4 Noise floor (dBm) –93 –90 –90 –85 –90 –76 –90 –90 –90 –89 –87 -88 -87 Receiver dynamic range (d
NETWORK ANALYZERS Ordering information Please specify model/order number, name and quantity when ordering. Model/Order No. Name 37147C 37169C Main frame Vector Network Analyzer (22.5 MHz to 20 GHz) Vector Network Analyzer (22.
NETWORK ANALYZERS BROADBAND VECTOR NETWORK ANALYZER ME7808A 40 MHz to 110 GHz Broadband S-Parameter Measurements to 110 GHz NEW GPIB The ME7808A Broadband Vector Network Analyzer (VNA) is a high performance measurement solution that covers 40 MHz to 110 GHz in a single fast sweep. In contrast to the millimeter wave Vector Network Analyzer, the ME7808A is built on the advanced technology of the Lightning 65 GHz VNA, and extends its advanced features and intuitive user interface to 110 GHz.
NETWORK ANALYZERS Specifications Dynamic range (typical) 0.
NETWORK ANALYZERS VECTOR NETWORK ANALYZER AUTOMATIC CALIBRATOR 3658 Series 10 MHz to 40 GHz Automatic, High-Reliability, and High-Quality Calibrators for Coaxial Device Measurements The 3658 series AutoCal® modules are automatic calibrators that provide fast, repeatable, and high-quality coaxial calibrations up to 40 GHz. These modules contain precisely characterized calibration standards that aid in the removal of normal systematic errors when using vector network analyzers (VNAs).
NETWORK ANALYZERS Specifications All specifications are guaranteed over the ambient temperature range of 23˚ ±3˚C. • Directivity AutoCal® module 38 dB AutoCal® with 36583X 36 dB 0.2 to 20 GHz 38 dB 36 dB 20 to 40 GHz 34 dB 32 dB AutoCal® module AutoCal® with 36583X 34 dB 32 dB Frequency 0.01 to 0.2 GHz • Source match Frequency 0.01 to 0.2 GHz 0.2 to 20 GHz 34 dB 32 dB 20 to 40 GHz 26 dB 24 dB AutoCal® module AutoCal® with 36583X ±0.15 dB ±0.20 dB 0.2 to 20 GHz ±0.20 dB ±0.
NETWORK ANALYZERS VNA AND VNMS Calibration Kits For Performing Precise Calibrations of Vector Network Analyzers 3651, Option 1 3753LF The Anritsu Calibration Kits contain all the precision components and tools required to calibrate your VNA or VNMS for 12-term errorcorrected measurements in the connector style of your choice. Components are included for calibrating male and female test ports as required. The kits support calibration with opens, shorts, and broadband loads.
NETWORK ANALYZERS 3654B V Connector® Calibration Kit consisting of: • 23V50B-5.1 Male Short 5.1mm • 23VF50B-5.1 Female Short 5.
NETWORK ANALYZERS VNA AND VNMS Verification Kits For Confirming Accuracy of Vector Network Analyzers 3667 GPC-7 Verification Kit consisting of: • 42A-50, 50 dB Attenuator • 18A50-10, 10 cm Air line • 42A-20, 20 dB Attenuator • 18A50-10B, 10 cm Stepped Impedance Airline (Beatty standard) • Verification kit disks 3668 K Connector® Verification Kit consisting of: • 19K50-7, 7.5 cm Airline • 42K-50, 50 dB Attenuator • 42K-20, 20 dB Attenuator • 18K50-7B, 7.
NETWORK ANALYZERS NETWORK ANALYZER 54100A Series 1 MHz to 110 GHz Fast and Accurate Scalar Network Measurements, with Built-in Source GPIB 7 54100A series Network Analyzers provide characterization of devices such as amplifiers, antennas, attenuators, adapters, RF bridges, duplexers, couplers, attenuators, cables, waveguide transmission lines, isolators, circulators, mixers, receivers, transceivers, up/down converters, multiplexers, power dividers, VCOs, switches, and filters.
NETWORK ANALYZERS • Adapters, attenuators, terminations, couplers, RF bridges The 54100A series precision return loss mode measures high return loss devices accurately traceable to NIST. The measurement system uses an offset SWR autotester and a precision airline — a physical impedance standard. Additionally, by exchanging the offset SWR autotester with a 20 dB offset termination, the directivity of couplers and RF bridges is displayed directly on the 54100A.
NETWORK ANALYZERS Measurement accuracy • Transmission loss or gain measurement accuracy Uncertainties from the frequency response of components are automatically subtracted from test data during the path calibration procedure. Overall accuracy is then: Channel accuracy + Mismatch uncertainty + Distortion from source harmonics Transmission measurement accuracy Effects of source, test device, SWR autotester, and detector mismatch can be significant.
NETWORK ANALYZERS General Application function Source Analyzer Specifications Measurement modes Transmission (dB), return loss (dB), SWR (linear SWR), optional group delay (ns), power (dBm) precision return loss (dB) and optional distance-to-fault Dynamic range –55 to +16 dBm, autozeroing with DC detection Inputs Three, two standard inputs, A and B, with optional third reference channel, R (Option 5) Display channels Two channels are used to select and simultaneously display any two inputs from
NETWORK ANALYZERS MILLIMETER WAVE MEASUREMENT SYSTEM 54000 Series 50 GHz to 110 GHz Scalar Measurements to 110 GHz from an Integrated System 54100A NETWORK ANALYZER (Option 16) +15Vdc R A B RF IN >+5 dBm 560-10BX-2 DETECTOR CABLE ANRITSU TRANSMISSION DETECTOR DUT REFLECTOMETER MILLIMETER WAVE TEST 5400-MMXXXX PORT Millimeter wave reflectometer configuration GPIB The Anritsu’s Millimeter Wave Reflectometers are designed to operate with the 54147A 20 GHz Network Analyzer.
NETWORK ANALYZERS Special Waveguide Reflectometers (Reflectometers have integrated multipliers/amplifiers. Input frequency is < 20 GHz) 54000-6WR15 Frequency range 50 to 75 GHz 54000-6WR10 75 to 110 GHz Test port 35 dB, 40 dB typ. SWR <1.9 (<1.7 typ.) Flange WR-15 Input connector N (f) 35 dB, 40 dB typ <1.9 (<1.7 typ.) WR-10 N (f) 54000-7WR15 Frequency range 50 to 75 GHz Dynamic range > 56 dB typ.
NETWORK ANALYZERS NETWORK ANALYZER MS4630B 10 Hz to 300 MHz For Fast Evaluation of IF Filters and Resonators GPIB 7 The MS4630B is suitable for electronics production lines demanding fast and accurate device measurements. It is particularly well suited to accurate, high-speed evaluation of IF filter resonance and group delay characteristics, as well as evaluating the impedance characteristics of resonators in AV equipment and personal computers.
NETWORK ANALYZERS • High-accuracy group delay measurement The group delay characteristics can be measured with a high degree of accuracy at a resolution of 1/10,000 of the measurement range. Set up menu for filter functions Group delay characteristics • Limit test function Device pass/fail evaluation can be performed in real-time using the single and segmented limit test functions.
NETWORK ANALYZERS Resonator 2 measurement Specifications Measurement items Frequency Transmission characteristics (ratio measurement): Amplitude, phase, group delay Reflection/impedance characteristics: Amplitude, phase (with external transducer) Level characteristics: Absolute amplitude Range: 10 Hz to 300 MHz Resolution: 0.
NETWORK ANALYZERS Measurement range: ±180˚ Measurement resolution: 0.001˚ Display scale: 0.01˚ to 50˚ /div (1-2-5 sequence) Dynamic accuracy Level relative to IRG Phase measurement 80 kHz to 100 MHz 10 kHz to 300 MHz 0 to –10 dB ±6.0˚ ±6.0˚ –10 to –60 dB ±0.3˚ ±0.3˚ –60 to –70 dB ±0.8˚ ±2.0˚ –70 to –80 dB ±2.0˚ ±6.0˚ –80 to –90 dB ±6.0˚ ±20.0˚ –90 to –100 dB ±20.
NETWORK ANALYZERS Back-panel I/O Frequency: 5/10 MHz ±10 ppm Level: ≥0.7 Vp-p (AC coupling) Input impedance: 50 Ω (connector: BNC-J) Reference oscillator output Frequency: 10 MHz Level: TTL (DC coupling, connector: BNC-J) External trigger input: TTL Level (connector: BNC-J) GPIB: IEEE488.
NETWORK ANALYZERS The 56100A Scalar Network Analyzer measures insertion loss, insertion gain, or RF power with 76 dB dynamic range. Measure device match as return loss in dB or as SWR. Separate detectors can be used on all four inputs for multiple transmission measurements on duplexers or matched amplifiers. Transmission and reflection measurements can be viewed simultaneously. Both traces can be scaled independently in dB, dBm, or SWR.