Specifications

http://www.anritsu.com 359
NETWORK ANALYZERS
7
PATS Software Results
With frequency sweeps as fast as 150 µs/point and power sweeps as
fast as 150 µs/point, you can quickly, thoroughly, and accurately
characterize your power amplifiers in real-time.
Simultaneously overlay measurements in both frequency and power
and see the results of over 250 datapoints updated twice per second.
Characteristic Value Notes
Amplifier Under Test
Power Output
100W max
Without Hot S
22
provision
(Contact Anritsu for custom designs
for higher power)
Port Match
(test ports 1 & 2)
13 dB min Uncorrected value
Directivity
Bandwidth through
Test Set
800 MHz –
2.4 GHZ
Without S
22
provision
(Contact Anritsu for custom designs
for different frequency ranges)
40 dB 800 MHz – 2.4 GHz, Corrected value
Amplifier Under Test
Input Power range
available from PATS
–85 dBm to
+10 dBm
This value is for each tone, at
combiner input. Provision for
preamplifiers provided for greater
levels
IMD (3
rd
order)
Dynamic Range
70 dB min
With 10 Hz IF bandwidth @ 300 kHz
tone separation and –20 dBm tone
levels
IMD Accuracy ±1 dB max @ >–60 dBc levels
Port Power Accuracy
±0.1 dB typical With flat power calibration
±1 dB max Without flat power calibration
Dynamic Range 80 dB min Over-all system including Test Set
Port Match
(test ports 1 & 2)
40 dB min Corrected value
Specifications
Model/Order No. Name
Main frame
ME7840A PATS, 800 to 2400 MHz, 100 Watts
MS4623C
1,2
Scorpion®, DRA configuration, 10 MHz to 6 GHz
MS4600/3D Scorpion® optional 6 GHz internal source with
3rd test port
MS4600/8 Scorpion® optional harmonic measurement application
MS4600/13 Scorpion® optional intermodulation distortion application
MS4782D PATS Test Set (100 Watts, 800 – 2400 MHz)
3
43425 Accessories and interconnect kit
Scorpion PA Navigator
ME7840/1 Replace MS4623C with MS4622C (3 GHz option)
ME7840/2 Replace MS4782D test set with MS4782A
ME7840/3 Delete Test Set
Circulators
Circulators may be required for measurements of Hot S
22
:
1000-50 Circulator, 800 – 1000 MHz, 20 dB min, 50 Watts
Max AUT Power
1000-52 Circulator, 1.8 – 2.5 GHz, 20 dB min, 50 Watts
Max AUT Power, (connecting cable(s) not included)
1000-53 Circulator, 1.8 – 2.5 GHz, 22 dB min, 79 Watts
Max AUT Power
Note: All circulators have 3 SMA female connectors.
Current Probes
Current Probes are required for drain current and Power
Added Efficiency (PAE) calculations:
2000-1067 Current Probe
Max current: 100mV/A:10A, 10mV/A:100A
Accuracy (at lesser current range setting):
3% of reading ±50mA
2000-1085 Current Probe
Max current: 1mV/mA:1A, 10mV/A:80A
Accuracy (at lesser current range setting):
2% of reading ±5mA
Calibration kits
3750LF SMA/3.5 mm RF Cal Kit (6 GHz)
3753LF Type N RF Cal Kit (6 GHz)
AutoCal
®
36581NNF/1 AutoCal, Type N, 10 MHz to 6 GHz
36581KKF/1 AutoCal, Type K, 10 MHz to 6 GHz
Economy cables
15LL50-0.3A 3.5 mm Male-Male Cable, 30 cm
15LL50-0.6A 3.5 mm Male-Male Cable, 60 cm
15LLF50-0.3A 3.5 mm Male-Female Cable, 30 cm
15LLF50-0.6A 3.5 mm Male-Female Cable, 60 cm
15NN50-0.3B Type N Male-Male Cable, 30 cm
15NN50-0.6B Type N Male-Male Cable, 60 cm
15NNF50-0.3B Type N Male-Female Cable, 30 cm
15NNF50-0.6B Type N Male-Female Cable, 60 cm
Ordering information
Please specify model/order number, name, and quantity when ordering.
Anritsu can configure and optimize a custom test set for your specif-
ic requirements. The following information represents the standard
configuration and options.
1: ME7840A standard connector type is N-female.
2: Scorpion
®
DRA rear panel Reference Channel Connectors a1, a2, b1,
and b2 are SMA-female connectors.
3: Special test sets can be configured for other power levels and frequency
ranges.