Specifications

http://www.anritsu.com 369
NETWORK ANALYZERS
7
Specifications
Dynamic range (typical)
Ordering information
Please specify model/order number, name, and quantity when ordering.
Name
Main frame
ME7808A Broadband Vector Network Analyzer
(includes 3742A-EW
1
millimeter wave modules,
broadband test set, frequency sources, multiplexing
couplers, and an equipment console for 40 MHz to
110 GHz functionality)
Options
Option 14 Split-Band (Microwave/mmW) VNA, replaces 65 GHz
(37397C) with 50 GHz (37377C) VNA, deletes
multiplexing coupler and 65 to 110 GHz mmW
modules. Select desired mmW modules separately.
Optional Millimeter-wave modules
3740A-V Transmission/Reflection Module, 50 to 75 GHz
3740A-E Transmission/Reflection Module, 60 to 90 GHz
3740A-EE Transmission/Reflection Module, 56 to 94 GHz
3740A-EW Transmission/Reflection Module, 65 to 110 GHz
3740A-W Transmission/Reflection Module, 75 to 110 GHz
3740A-F Transmission/Reflection Module, 90 to 140 GHz
Test Port Cables
806-101 Flexible, V female to V male
3670V50-2 Semi-rigid, V female to V male
2
Semi-rigid, W1 male to W1 male
Model/Order No. Name
Calibration Kits
3654B V-connector calibration kit with sliding terminations
3655W WR-10 waveguide calibration kit
3655W-1 WR-10 waveguide calibration kit with sliding terminations
Adapters (coaxial)
2
W1 male to V male
2
W1 male to V female
2
W1 female to V male
2
W1 female to V female
2
W1 male to W1 male
2
W1 male to W1 female
2
W1 female to W1 female
Adapters (waveguide to coaxial)
2
WR-10 to W1 male
2
WR-10 to W1 female
On-Wafer Test Probes and Substrates
(GGB Picoprobe
®
)
110H 110 GHz wafer probe, W1 female
67A 67 GHz wafer probe, V female
120 w/out Bias T Extended W band wafer probe, WR10
120 w/ Bias T Extended W band wafer probe, WR10, with bias tee
CS5 Calibration substrate
Model/Order No.
System dynamic range is defined as the ratio of the typical power at Port 1 and the system noise floor.
The noise floor measurement is made using 512 averages in a 100 Hz IF bandwidth, including isolation calibration.
Frequency (GHz)
0.04 2 20 40 50 <65 >65 75 85 100 110
Max Signal into Port 2 (dBm) 30 30 30 30 30 30 16 14 13 12 12
Port 1 Power, Typical (dBm) -1 3 -7 -14 -10 -12 -14 -10 -11 -9 -11
Noise Floor (dBm) -76 -103 -92 -88 -79 -67 -65 -78 -81 -78 -73
System Dynamic Range (dB) 75 106 85 74 69 55 51 68 70 69 62
Receiver Dynamic Range (dB) 106 133 122 118 109 97 81 92 94 90 85
W1 Coaxial Port
V Coaxial Port
Frequency (GHz) 0.04 2 20 40 50 65
Max Signal into Port 2 (dBm) 30 30 30 30 30 30
Port 1 Power, Typical (dBm) 0 5 -2 -7 -2 -2
Noise Floor (dBm) -77 -105 -97 -95 -87 -77
System Dynamic Range (dB) 77 110 95 88 85 75
Receiver Dynamic Range (dB) 107 135 127 125 117 107
Frequency (GHz) 0.04 2 20 40 50 <65 >65 75 85 100 110
Max Signal into Port 2 (dBm) 30 30 30 30 30 30 18 17 16 16 16
Port 1 Power, Typical (dBm) -1 3 -8 -16 -12 -14 -16 -13 -14 -13 -15
Noise Floor (dBm) -76 -103 -91 -86 -77 -65 -63 -75 -78 -74 -69
System Dynamic Range (dB) 75 106 83 70 65 51 47 62 64 61 54
Receiver Dynamic Range (dB) 106 133 121 116 107 95 81 92 94 90 85
On Wafer
WR-10 Waveguide
Frequency (GHz) 65 75 85 100 110
Max Signal into Port 2 (dBm) 8 8 8 8 8
Port 1 Power, Typical (dBm) -6 -4 -6 -5 -7
Noise Floor (dBm) -73 -84 -86 -82 -77
System Dynamic Range (dB) 67 80 80 77 70
Receiver Dynamic Range (dB) 81 92 94 90 85
Measurement time for 101 data points (typical)
Measurement time is based on a single 40 MHz to 110 GHz sweep with 10 kHz
IF bandwidth (no averages) after full 12-term calibration. Sweep time includes
retrace and band switch times.
Frequency Span
40 MHz to 110 GHz
Time (s) 1.5
1: 3742A-EW modules are equipped with an adjustable attenuator that is
not available in the 3740A.
2: Contact factory to place an order for the item.