Specifications

NETWORK ANALYZERS
384 For product ordering information, see pages 4 10
Measurement range: ±180˚
Measurement resolution: 0.001˚
Display scale: 0.01˚ to 50˚ /div (1-2-5 sequence)
Dynamic accuracy
Phase measurement
DRG: θ/(360 x F) θ: phase measurement range; F: frequency span x smoothing aperture (%);
smoothing aperture: 20% to
(
2
)
x 100%
Group delay
number measurement points
measurement
Measurement resolution: 2.78 x 10
5
/F
Display scale: 1 ps/div to 50 ms/div
Dynamic accuracy: Phase measurement accuracy/(360 x aperture frequency)
Calibration types: Frequency response, 1 port, 1 path-2 port, frequency response/isolation calibration, π-NET calibration
Calibration data interpolation:
Measurement frequency, when number of measurement points changed, based on calibration data before change, new calibration
data interpolation calculation possible (except at log frequency measurement and 1001 measurement points)
Calibration, correction
Normalize: XS
Electrical length calibration
Range: 0 to ±999999.9999999 m, Resolution: 100 nm
Phase offset range: ±180˚
Frequency sweep: LIN (CENTER/SPAN, START/STOP), LOG (START/STOP)
Level sweep: LIN (START/STOP/STEP)
List sweep: Frequency, level, RBW, the individual setting in the waiting time
Number of measurement points: 11, 21, 51, 101, 251, 501, 1001
Break point: Anywhere between 1 and 1001
Sweeping Sweep time: 150 µs/point, 38 ms/250 points full sweep (RBW: 20 kHz, normalize calibration, 1 trace)
Setting range: 1 ms to 27.5 h
Sweep functions
Sweep range: Full sweep, part sweep (between markers)
Sweep control: REPEAT/SINGLE, STOP/CONT
Sweep trigger: INT/EXT (RISE, FALL, LEVEL)
Max. display screens: 2 channels, 4 traces
Display
Display format: LOG MAG (M), PHASE (P), DELAY (D), M/P, M/D, LIN MAG (LIN), LIN/P, LIN/D, REAL (R), IMAG (I), R/I, Z, Z/
θ, Q,
Z/Q, POLAR, VSWR, IMPD (Z
∠θ, Rs + Ls/Cs, Q/D, R + jx), ADMT (Y∠θ, Rp + Lp/Cp, Q/D, G + jB)
Display: 640 x 480 dots, 16.5 cm color LCD
Marker functions: NORMAL MKR, MKR, 0 MKR, MKR
MAX, MKR
MIN, MKR
CF,
SPAN, MKR
+PEAK,
MKR
PEAK, MKR TRACK + PEAK, MKR TRACKPEAK, MKR CHANGE, MKR OFFSET
Setting: Set marker position to frequency or point
Markers
Multi-marker: Max. 10 markers for each trace
Filter function: F0, IL, passband (L, R), attenuation band (L, R), Ripple, Q, SF
Resonator function
RESON 1: Fr, Fa, Zr, Za (0 PHASE), Fm, Fn, Zm, Zn (MAX/MIN)
RESON 2: Fs, Fr, Fa, Zr, Za, Q, equivalence constant (R1, L1, C1, C0)
Averaging functions
Method: SUM, MAX, MIN, Count: 1 to 1000
Measurement data memory (max. 1001 points each memory in same format as display format)
Main trace (MT) memory: 2 each (XMEM) for Channel 1 and Channel 2
Trace data calculation
Calibration S memory: 2 each (SMEM) for Channel 1 and Channel 2
Image memory: 2 each (IMEM) for Channel 1 and Channel 2
Sub-trace (ST): Following calculation between MT and ST (traces calculation of same data as display format)
MT
ST, MT = MTST, MT = ST
Limit line: Single or segment (10) limit line, pass/fail evaluation against limit line
Measurement
parameters
Receive bandwidth and sweep time: Receive bandwidth set automatically for set sweep time
auto-setting
Automatically set to give minimum sweep time at set receive bandwidth
Saving/recalling data:
Measurement parameters, measured data, calibration data, PTA application programs saved/recalled to/from FD and PMC
Function memory
FD: 100 functions max.
Auxiliary media PMC: 100 functions max. (depends on PMC capacity)
Drive and capacity
3.5 inch FDD: 1
Capacity: 720 KB (2DD), 1.44 MB (2HD), MS-DOS format (bmt, text file)
Option 01: PMC (32 to 512 KB)
Printing Printing is available using video plotter, printer and FD (bitmap format).
Level relative to IRG 80 kHz to 100 MHz 10 kHz to 300 MHz
0 to 10 dB ±6.0˚ ±6.0˚
10 to 60 dB ±0.3˚ ±0.3˚
60 to 70 dB ±0.8˚ ±2.0˚
70 to 80 dB ±2.0˚ ±6.0˚
80 to 90 dB ±6.0˚ ±20.0˚
90 to 100 dB ±20.0˚
Continued on next page