Specifications
Menu Name Function Description GPIB Mnemonic
AUTOCAL
ASSURANCE
LIMITS 2
Displays with a 2-port AutoCal box.
LOAD MATCH
DC - 2 GHZ
37.0 DB
2-6 GHZ
37.0 DB
Changes the values of AutoCal load match limits.
The values are defaulted to 37.0 dB.
ACALM1; ACALM1?;
ACALM2; ACALM2?
TRANSMISSION
TRACKING
DC - 2 GHZ
0.150 DB
2-6GHZ
0.200 DB
Changes the values of AutoCal transmission
tracking limits. The values are defaulted to
0.150 dB for DC to 2 GHz and
0.200 dB for 2 to 6 GHz.
ACATRT1;
ACATRT1?;
ACATRT2;
ACATRT2?
MORE Changes the soft-key display to the appropriate
AUTOCAL ASSURANCE LIMITS menu.
None
RETURN Changes the soft-key display to the AUTOCAL
ASSURANCE menu.
None
AUTOCAL
ASSURANCE
LIMITS
Displays in MS4622X with a 4-port AutoCal box.
DIRECTIVITY
DC - 3 GHZ
40.0 DB
Changes the value of AutoCal directivity limits. The
value is defaulted to 40.0 dB.
ACADIR1; ACADIR1?
SOURCE MATCH
DC - 3 GHZ
38.0 DB
Changes the value of AutoCal source match limits.
The value is defaulted to 38.0 dB.
ACASRC1;
ACASRC1?
REFLECTION TRACKING
DC - 3 GHZ
0.150 DB
Changes the value of AutoCal reflection tracking
limits. The value is defaulted to 0.150 dB.
ACARET1;
ACARET1?
LOAD MATCH
DC - 3 GHZ
40.0 DB
Changes the value of AutoCal load match limits. The
value is defaulted to 40.0 dB.
ACALM1; ACALM1?
TRANSMISSION
TRACKING
DC - 3 GHZ
0.150 DB
Changes the value of AutoCal transmission tracking
limits. The value is defaulted to 0.150 dB.
ACATRT1;
ACATRT1?
RETURN Changes the soft-key display to the AUTOCAL
ASSURANCE menu.
None
FRONT PANEL UTILITY
OPERATION KEY MENUS
MS462XX OM 4-89