Specifications

D-30 MS462XX OM
Calibration Key Menu Map (Transmission & Reflection)(4 of 17) APPENDIX D
*Ax
A
NEXT CAL STEP
LINE TYPE
METHOD AND
CHANGE CAL
XXX
LINE TYPE:
XXX
CAL METHOD
PREVIOUS CAL
REPEAT
CAL DATA
KEEP EXISTING
(12 TERMS)
CALIBRATION
BEGIN 2 PORT
ONLY
REFLECTION
RESPONSE
FREQUENCY
TRANSMISSION
2 PORT
1PATH
FULL 12-TERM
CALIBRATION TYPE
SELECT
NEXT CAL STEP
MICROSTRIP
WAVEGUIDE
COAXIAL
LINE TYPE
TRM
LRL/LRM
OFFSET SHORT
WAVEGUIDE)
USED FOR
STANDARD (NOT
CAL METHOD
AND LINE TYPE
CHANGE CAL METHOD
(S22, S12)
REVERSE PATH
(S11, S21)
FORWARD PATH
CALIBRATION TYPE
1PATH2PORT
SELECT
(S21, S12)
BOTH PATHS
(S12)
REVERSE PATH
(S21)
FORWARD PATH
CALIBRATION TYPE
FREQ RESPONSE
TRANSMISSION
SELECT
EXCLUDE ISOLATION
(STANDARD)
ISOLATION
INCLUDE
IN CALIBRATION
OF ISOLATION
SELECT USE
(S11, S22)
BOTH PATHS
(S22)
PORT 2 ONLY
(S11)
PORT 1 ONLY
CALIBRATION TYPE
REFLECTION ONLY
SELECT
NEXT CAL STEP
STEPSIZE
xxxxxxxxxxxx GHz
xxx DATA POINT(S)
DATA POINTS
SET CENTER/SPAN
xxx.xxxxxxxxx GHz
STOP
xxx.xxxxxxxxx GHz
START
CAL FREQ RANGE
NEXT CAL STEP
STEPSIZE
xxxxxxxxxxxx Ghz
xxx DATA POINT(S)
DATA POINTS
SET START/STOP
xxx.xxxxxxxxx GHz
SPAN
xxx.xxxxxxxxx GHz
CENTER
CAL FREQ RANGE
3 MAX POINTS
15 MAX POINTS
51 MAX POINTS
101 MAX POINTS
201 MAX POINTS
401 MAX POINTS
801 MAX POINTS
1601 MAX POINTS
DATA POINTS
NEXT CAL STEP
CLEAR ALL
FREQ INSERT
INDIVIDUAL
( xxx ENTERED )
FILL THE RANGE
xxx.xxxxxxxxx GHz
STOP FREQ
xx POINT(S)
NUMBER OF POINTS
xxx.xxxxxxxxx GHz
INCREMENT
xxx.xxxxxxxxxx GHz
START FREQ
DISCRETE FILL
RETURN
xxx.xxxxxxxxx GHz
AUTO INCR ON / OFF
xxx.xxxxxxxxx GHz
LAST FREQ WAS
ENTERED.
xx FREQS
FREQUENCY
INSERT NEXT
xxx.xxxxxxxxxx GHz
NEXT FREQUENCY
INSERT
FREQUENCY
INDIVIDUAL
A
Page D-15
If CAL METHOD is LRL/LRM
*Ax
NEXT CAL STEP
xxx.xxxxxxxxx GHz
C. W. FREQ
C.W.CALIBRATION
SINGLE POINT
*Ax
NEXT CAL STEP
TRUE STOP FREQ
xxx.xxxxxxxxx GHz
xxxxx DATA POINTS
WILL RESULT IN
START AND STOP
USING ABOVE
xxx.xxxxxxxxx GHz
APPROXIMATE STOP
xxx.xxxxxxxxxx GHz
START (STEP)
FOR TIME DOMAIN
HAMONIC CAL
RANGE
CALIBRATION
*Ax
*Ax
*Ax
* Ax indicates maps A1 thru A8 that appear
on other sheets within this menu set. Which
set A1, A2, A3, A4, A5, A6, A7, or A8 depends
on CAL METHOD and/or LINE TYPE.
(HARMONIC)
TIME DOMAIN
POINTS)
(2 TO 1601
FREQUENCIES
N-DISCRETE
(1 POINT)
C.W.
MAXIMUM
(1601 POINTS
NORMAL
DATA POINTS
CALIBRATION
SELECT
SEGMENTED SWEEP
(1601 POINTS
MAXIMUM)
CAL FREQ RANGE
START
MHZ
STOP
MHZ
xx.xxxxxx
xx.xxxxxx
DATA POINTS
XXX DATA POINTS
STEP SIZE
VARIABLE FOR
SEGMENTED
SWEEP
NEXT CAL STEP