Specifications

Menu Name Function Description GPIB Mnemonic
D.C. TERM
SETUP FOR
LOWPASS
PROCESSING
AUTO EXTRAPOLATE Sets the D.C. term to a value determined by
extrapolating the data points near the zero
frequency.
DCA; DCX?
LINE
IMPEDANCE
Sets the D.C. term to the characteristic
impedance of the transmission medium (Z0).
DCZ
OPEN Sets the D.C. term to correspond to an open
circuit.
DCO
SHORT Sets the D.C. term to correspond to a short
circuit.
DCS
OTHER
XXX.XXX
Sets the D.C. term to the value entered. DCV
(REFLECTION
COEFFICIENT
X.XXX pU)
Displays the reflection coefficient value. DCX?
RETURN Returns to the previous soft-key menu. None
DISTANCE
MARKER SWEEP
START MARKER ( )
XX.XXXX cm
Sets the start distance to the value of the
selected marker.
M1S thru M12S
STOP MARKER ( )
XX.XXXXcm
Sets the stop distance to the value of the
selected marker.
M1E thru M12E
RESTORE
ORGINAL RANGE
Returns the display to the original distance
range that was in effect before the marker
range was selected.
MRR
RETURN Returns to the previous soft-key menu. None
DOMAIN
SELECT DOMAIN None
FREQUENCY,
NO TIME GATE
Displays the data in the frequency domain, with
no time gate.
FQD; TDX?
FREQUENCY,
WITH TIME GATE
Displays the data in the frequency domain,
after a specific time range has been sampled
by the gate function.
FGT
TIME,
LOWPASS
Displays the data in the time (distance) domain,
using true lowpass processing. Data must be
taken using a harmonic series calibration and
sweep.
TLP
TIME,
BANDPASS
Displays the data in the time (distance) domain
using bandpass processing. Any data sweep
range using normal calibration can be used.
TBP
DISPLAY
TIME/DISTANCE
Toggles between TIME and DISTANCE display
when TIME LOWPASS or TIME BANDPASS
mode is selected.
TDDIST; TDTIME;
TDDIST?
SETUP Changes the soft-key display to the DOMAIN 2
menu.
None
HELP ON/OFF Displays an informational help screen. HELP1; HELP0; HELPX?
APPL FRONT PANEL
KEY MENUS OPERATION
4-8 MS462XX OM