Specifications
10 Product Brochure
l
MX3700xxA
CDMA2000 1xEV-DO Waveform Patterns
Standard
■
CDMA2000 1xEV-DO Waveform Patterns
The CDMA2000 1xEV-DO waveform patterns listed opposite are
stored on the MG3700A internal hard disk.
The 3GPP2 signals specified for testing receivers and transmitters
of CDMA2000 1xEV-DO access networks (base station) and
access terminal (AT) are output by selecting one of the 13 forward
and 10 reverse data rate patterns.
When multi-carrier signals, mixed idle and active signals and/or
multi-user signals are required, the optional MX370103A
CDMA2000 1xEV-DO IQproducer application, software can be
used to set parameters and generate waveform patterns.
Selecting Waveform Pattern
•
Access Terminal (AT) Receiver Test
CDMA2000 1xEV-DO forward
Baseband filter: IS-95 SPEC +EQ
Data: PN15 fix
∗
(excluding FWD-Idle)
FWD_38_4kbps_16slot
FWD_76_8kbps_8slot
FWD_153_6kbps_4slot
FWD_307_2kbps_2slot
FWD_614_4kbps_1slot
FWD_307_2kbps_4slot
FWD_614_4kbps_2slot
FWD_1228_8kbps_1slot
FWD_921_6kbps_2slot
FWD_1843_2kbps_1slot
FWD_1228_8kbps_2slot
FWD_2457_6kbps_1slot
FWD_Idle
•
Access Network (AN) Receiver Test
CDMA2000 1xEV-DO Reverse
Baseband filter: IS-95 SPEC
Data: PN9 fix
∗
RVS_9_6kbps_RX
RVS_19_2kbps_RX
RVS_38_4kbps_RX
RVS_76_8kbps_RX
RVS_153_6kbps_RX
RVS_9_6kbps_TX
RVS_19_2kbps_TX
RVS_38_4kbps_TX
RVS_76_8kbps_RT
RVS_153_6kbps_RT
∗: This displays the delimited PN sequence for each packet.
Therefore, the PN sequence is discontinuous between the end data of one
packet and the header data of the next packet.
•
Access Terminal (AT) Receiver Test
3GPP2 C.S0033 standard receiver tests (PER: Packet Error Rate) can be performed by selecting a forward signal pattern for
testing the AT. Since protocols are not supported for the access network simulator and all transmission channels are traffic, while all
other channels (Sync, etc.) are unsupported., an external controller (PC) must be used to control the AT and calculate the PER.
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com