Specifications
30 Product Brochure
l
MX3701xxA
● Parameter Setting Items
No. Segment Items Setting Range Restriction
∗
1
1
Physical
Layer
System DVB-T, DVB-H
2 Transmission Non-hierarchical, Hierarchical
3 Alpha 1, 2, 4 1: When No.2 = Non-hierarchical
4 Mode (Sub-carrier of OFDM) 2K, 4K, 8K "4K" cannot be set when No.1 = DVB-T.
5 Bandwidth 5 MHz, 6 MHz, 7 MHz, 8 MHz "5 MHz" cannot be set when No.1 = DVB-T.
6 Modulation Type QPSK, 16QAM, 64QAM "QPSK" cannot be set when No.2 = Hierarchical
7 Guard Interval 1/4, 1/8, 1/16, 1/32
8 User Cell ID ON: 0000 to FFFF (HEX), OFF "ON": When No.1 = DVB-H
9
Function
Outer Coder ON, OFF "LP" cannot be set when No.2 = Non-hierarchical.OFF:
When No.10 = OFF
10 Outer Interleaver ON, OFF "LP" cannot be set when No.2 = Non-hierarchical. ON:
When No.9 = ON
OFF: When No.11 = OFF
11 Inner Coder ON, OFF "LP" cannot be set when No.2 = Non-hierarchical. ON:
When No.10 = ON
OFF: When No.13 = OFF
12 Code Rate 1/2, 2/3, 3/4, 5/6, 7/8 "LP" cannot be set when No.2 = Non-hierarchical.
Cannot be set when No.11 = OFF
13 Inner Interleaver ON, OFF ON: When No.11 = ON
14
Data Pattern
(Data) PN9, PN15, PN23, ALL0, ALL1, 0101, Null TS, TS File "LP" cannot be set when No.2 = Non-hierarchical.
When TS File is selected, the external TS le is read. The TS le is composed of several packets with 188 bytes/
packet. The rst one byte of the packet becomes the Sync Byte and is set to 47 (HEX). If a TS le that does not
follow the format of this TS data is selected, an error is displayed when the Calculation button is clicked.
When all of "Outer Coder," "Outer Interleaver," "Inner Coder," and "Inner Interleaver" are set to ON, Sync Byte is
set to the data of "PN9/PN15/PN23/ALL0/ALL1/0101". At this time, the continuity of data is kept between the "last
data of the packet" and the "rst data of the next packet except the Sync Byte."
∗
2
15 Number of Super
Frames
1 to 384 (See following for details.)
16
DVB-H
In-depth Symbol
Interleaver
ON, OFF OFF: When No.1 = DVB-T
OFF: When No.4 = 8K
OFF: When No.13 = OFF
17 Time Slicing ON, OFF: When Time Slicing = ON, the 49th bit of the
TPS data is set to "1".
When Data Pattern = TS File, Time Slicing
processing is required in the selected TS le.
OFF: No.1 = DVB-T
"LP" cannot be set when No.2 = Non-hierarchical.
18 MPE-FEC ON, OFF: When MPE-FEC = ON, the 50th bit of the
TPS data is set to "1".
When Data Pattern = TS File, MPE-FEC
processing is required in the selected TS le.
OFF: When No.1 = DVB-T
"LP" cannot be set when No.2 = Non-hierarchical.
19
Filter
(Type) None, Nyquist, Root Nyquist, Gaussian, Ideal Lowpass
20 Roll Off/BT 0.100 to 1.000 Cannot be set when No.19 = None/Ideal Lowpass
21 Symbol Length 1 to 1023 Cannot be set when No.19 = None/Ideal Lowpass
1: When No.19 = None
1023: When No.19 = Ideal Lowpass
22 Multipath OFF, F1, P1
∗ 1: Other parameter setting conditions limited by setting range restrictions
∗ 2: Packet continuity shown in following figure
MX370106A DVB-T/H IQproducer
Optional
The data processing changes according to the "Size of TS File"
and "Setting of Number of Super Frames" when TS File is selected
at "Data Pattern". The TS File data is annulled when the "TS File
data number" is greater than the "Data number equivalent to the
set number of super frames." When the "TS File data number" is
smaller than the "Data number equivalent to the set number of
super frames", the same TS File data is repeated from the header.
● Number of Super Frame Setting
The "Number of Super Frame" setting range changes according to
the "Mode" setting and "MG3700A main frame memory option" as
shown in the following table.
Maximum Number of
Super Frame
Memory Option Mode
384
With Option 021
(ARB Memory Upgrade
512 Msamples)
2 k
192 4 k
96 8 k
192
Without Option 021
2 k
96 4 k
48 8 k
The data selected by "Data Pattern" is annulled in the terminal of
the final super frame set here.
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com