335) Frequency Scale Factor
182
(higher byte)
336) Frequency Scale Factor (lower byte)
337) Frequency Range Minimum
183
(highest byte)
338) Frequency Range Minimum
339) Frequency Range Minimum
340) Frequency Range Minimum (lowest byte)
341) Frequency Range Maximum
184
(highest byte)
342) Frequency Range Maximum
343) Frequency Range Maximum
344) Frequency Range Maximum (lowest byte)
345) Linked Trace Number (1-200)
346) Status Byte 9 (0b=Off, 1b=On)
(LSB) bit 0 : C/I Measurement On/Off
bits 1-3 : C/I Carrier Trace/Signal Type
185
bits 4-7 : Not Used
347) C/I Calculated Power
186
(Carrier or Interference - NB FHSS
187
) (highest byte)
348) C/I Calculated Power (Carrier or Interference - NB FHSS) (lowest byte)
349) C/I Calculated Power (Carrier or Interference - NB FHSS) (highest byte)
350) C/I Calculated Power (Carrier or Interference - NB FHSS) (lowest byte)
351) C/I Calculated Power
188
(Interference - WB FHSS
189
) (highest byte)
352) C/I Calculated Power (Interference - WB FHSS) (lowest byte)
353) C/I Calculated Power (Interference - WB FHSS) (highest byte)
354) C/I Calculated Power (Interference - WB FHSS) (lowest byte)
355) C/I Calculated Power
190
(Interference - Broadband
191
) (highest byte)
356) C/I Calculated Power (Interference - Broadband) (lowest byte)
357) C/I Calculated Power (Interference - Broadband) (highest byte)
358) C/I Calculated Power (Interference - Broadband) (lowest byte)
359) Occupied BW Power
192
(highest byte)
360) Occupied BW Power
361) Occupied BW Power
362) Occupied BW Power (lowest byte)
363) Marker Type
193
364-431) Not Used
432-2035) Sweep Data (401 points * 4 bytes/point= 1604 bytes)
4 bytes for each data point
Site Master PM 57
182 In number of Hz
183 Scaled by Frequency Scale Factor (bytes 335-336)
184 Scaled by Frequency Scale Factor (bytes 335-336)
185 000b = NB FHSS, 001b = Carrier - WB FHSS, 010b = Carrier - Broadband, 111b = Interference
186 Value sent as (value in dBm * 1000) + 270,000
187 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a NB FHSS
signal. Otherwise, these bytes represent the calculated carrier power.
188 Value sent as (value in dBm * 1000) + 270,000
189 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a WB FHSS
signal. Otherwise, these bytes should be ignored.
190 Value sent as (value in dBm * 1000) + 270,000
191 If Status Byte 9, bits 1-3 equal 111b, then value will be calculated power for the interference trace as a Broadband
signal. Otherwise, these bytes should be ignored.
192 If Method is % of power, then the value is dB Down * 1000. If the Method is db Down, then the value is %.
193 00h = Regular Marker, 01h = Noise Marker