User's Manual

[12]
[a]
[7]
Fig.2 Attaching the barrelled action
X Run the cleaning wick through the barrel from the chamber towards the
muzzle several times.
For correct tightening of the action screws [a],
ANSCHÜTZ recommends the use of a torque
wrench, starting at 2.5 Nm and not to exceed 4.0
Nm. Excessive screw torque may cause damage.
If you have further questions contact your service
center.
NOTE!
Danger to life!
Unintentional discharge as a result of a loaded, unse-
cured rifle.
h Keep the muzzle of the firearm pointing in a safe direc-
tion.
h Engage the safety catch after loading the rifle.
WARNING!
Settling of the stock wood can occur after the initial
assembly of the barrelled action [7].
ANSCHÜTZ therefore recommends loosening the
action screws [a] after a time and tightening them
again in accordance with Chapter 8.
NOTE!
I The attachment of the barrelled action must be checked each time before shooting to
ensure that it is secure.
Danger to life!
Unintentional discharge as a result of inattentiveness
while engaging the safety catch or as a result of possi-
ble malfunctions after securing.
h Even when the safety catch is engaged, the muzzle
of a firearm must never be held in a direction where
it can can cause damage
or endanger life.
WARNING!
10