User Manual

Antaira Industrial Ethernet Switches
LMX-0601G-SFP Series User Manual V1.1
28
[RPL Owner Node]
There is only one RPL Owner Node that can be set in a ring network. In order to set up the
RPL Owner Node, choose a switch and enable the “Protocol” under the ERPS Configuration
interface, and follow the steps below (Figure 5.25).
Step 1:
Choose a specific port from the dropdown box next to “ring port 0”, and set it as
“Owner” node by clicking the dropdown box next to “Role” below “ring port 0”.
At this point, “Port 1” was chosen as example.
Step 2: Choose a specific port from the dropdown box next to “ring port 1”, then set it as
“Normal” from the dropdown box next to “Role” (which locates below “ring port
1”). At this point, “Port 2” was chosen as example.
Note: The port number of “Ring Port 0” and “Ring Port 1” cannot be duplicated.
After the configurations, press the “Apply” button on the right bottom corner to save the
setting.
Please note, when the revertive mode is set to “Yes”, the ring will recover the same
information as shown in Figure 5.24, after, the ring state will go from ABNORMAL to
NORMAL within 5 minutes. Otherwise, the blocked port will remain blocked permanently
unless users reconfigure it.
Figure 5.21 – RPL Owner Node Setup Example