User Manual

Antaira Industrial Ethernet Switches
LMX-0601G-SFP Series User Manual V1.1
29
[RPL Neighbor Node]
Users should choose a second managed switch that is adjacent to the first managed switch
and set it up as the RPL neighbor node. For configuration, users should login to the second
managed switch’s ERPS configuration interface and choose a specific port number under
“Ring Port 0” and set it as the “Normal” node by clicking the dropdown box of “Role”; then, set
another specific port number under “Ring Port 1” as the “Neighbor” node as shown below in
Figure 5.22. So the link between neighbor port and owner port forms the ring protection link
(RPL). After the configurations, press the “Apply” button on the bottom right corner to save the
settings.
Note: The port number of “Ring Port 0” and “Ring Port 1” cannot be duplicated.
Figure 5.22 – RPL Neighbor Node Setup Example