Application Guide

[220]
Software User's
Manual
Version 3.0
Diagnostics > VeriPHY
VeriPHY Cable Diagnostics
This page is used for running the VeriPHY Cable Diagnostics for 10/100 and 1G copper ports.
Press Start to run the diagnostics. This will take approximately 5 seconds. If all ports are selected, this
can take approximately 15 seconds. When completed, the page refreshes automatically, and you can
view the cable diagnostics results in the cable status table. Note that VeriPHY is only accurate for
cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a
10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete.
Cable Status
Setting Description
Port Port number.
Pair
The status of the cable pair.
OK - Correctly terminated pair.
Open - Open pair.
Short - Shorted pair.
Short A - Cross-pair short to pair A.
Short B - Cross-pair short to pair B.
Short C - Cross-pair short to pair C.
Short D - Cross-pair short to pair D.
Cross A - Abnormal cross-pair coupling with pair A.
Cross B - Abnormal cross-pair coupling with pair B.
Cross C - Abnormal cross-pair coupling with pair C.
Cross D - Abnormal cross-pair coupling with pair D.
Length The length (in meters) of the cable pair. The resolution is 3 meters.