Application Guide

[79]
Software User's
Manual
Version 3.0
Logging
Specify the logging operation of the ACE. Notice that the logging message doesn't include the 4 bytes
CRC information.
Setting Description
Factory
Default
Enabled Frames matching the ACE are stored in the System Log.
Disabled
Disabled Frames matching the ACE are not logged.
NOTE: The logging feature only works when the packet length is less than 1518(without VLAN
tags) and the System Log memory size and logging rate is limited.
Shutdown
Setting Description
Factory
Default
Enabled If a frame matches the ACE, the ingress port will be disabled.
Disabled
Disabled Port shut down is disabled for the ACE.
NOTE: The shutdown feature only works when the packet length is less than 1518(without VLAN
tags).
Counter
The counter indicates the number of times the ACE was hit by a frame.
MAC Parameters
(Only displayed when the frame type is Ethernet Type or ARP.)
SMAC Filter
Setting Description
Factory
Default
Any No SMAC filter is specified.
Any
Specific
If you want to filter a specific source MAC address with this ACE,
choose this value. A field for entering a SMAC value appears.
SMAC Value
Setting Description
Factory
Default