Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 LNX-C500 Series 5-Port Industrial Compact Unmanaged Ethernet Switches with 5*10/100Tx, 12~48VDC Power Input Version 1.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 © Copyright 2018 Antaira Technologies, LLC. All Rights Reserved This document contains information, which is protected by copyright. Reproduction, adaptation or translation without prior permission is prohibited, except as allowed under the copyright laws. Trademark Information Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 FCC Notice This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 Table of Contents 1. Overview....................................................................... 1 1.1 Key Features ...................................................... 1 1.2 Package Contents .............................................. 2 1.3 Safety Precaution ............................................... 2 2. Hardware Description ................................................. 3 2.1 Physical Dimensions .......
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 1. Overview Antaira Technologies’ LNX-C500 series is a compact 5-port industrial Ethernet switch. The small form factor of this metal IP30 rated industrial switch is 30% smaller allowing for a more versatile implementation. The LNX-C500 is equipped with 5*10/100 RJ45 Ethernet ports with a backplane speed of 1gbps and is designed for industrial network expansion applications with tight spaces.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 1.2 Package Contents 1 - LNX-C500 (-T): 5-port industrial compact unmanaged Ethernet switch with 5*10/100Tx 2 - Wall mounting brackets and screws 1 - DC cable –18 AWG & DC jack 5.5x2.1mm 1.3 Safety Precaution Attention: If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 2. Hardware Description 2.1 Physical Dimensions Figure 2.1, below, shows the physical dimensions of Antaira Technologies’ LNX-C500 series: 5port compact industrial unmanaged Ethernet switch with 5*10/100Tx RJ45 ports. (W x D x H) is 26mm x 75mm x 95mm Figure 2.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 2.2 Front Panel The front panel of the LNX-C500 series: 5-port industrial compact unmanaged Ethernet switch with 5*10/100Tx. See Figure 2.2. 4-pin removal terminal block (power input) Grounding screw LED for PWR LAN Port # 1~5 – 10/100Tx LED for 100Tx data transmission LED for 10Tx network speed Figure 2.2 Front Panel of the LNX-C500 Series 2.3 Top View Figure 2.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 2.4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 All ports on this industrial Ethernet switch support automatic MDI operations. Users can use straight-through cables (see figure below) for all network connections to PCs, servers, and other switches or hubs. With straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below (Table 2.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 2.7 Wiring the Power Inputs Please follow the below steps to insert the power wire. 1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 2.6. Figure 2.6 Power Terminal Block 2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.7. Figure 2.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 3. Mounting Installation 3.1 DIN-Rail Mounting The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is not on the industrial Ethernet switch, please refer to Figure 3.1 to learn how to install the DINRail on the switch. Figure 3.1 The Rear Side of the Switch and DIN-Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch. 1.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 3.2 Wall Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3.4. 1. Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the screws. 2. Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch. 3. Use the screws to screw the wall mounting bracket on the industrial Ethernet switch. 4.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 4. Hardware Installation 4.1 Installation Steps This section will explain how to install Antaira Technologies’ LNX-C500 (T): 5-port compact industrial compact unmanaged Ethernet switch with 5*10/100Tx ports. Installation Steps 1. Unpack the industrial Ethernet switch from the original packing box. 2. Check if the DIN-Rail bracket is screwed on the industrial Ethernet switch.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 5. Trouble Shooting Always verify the right power cord or adapter is being used. Never use a power supply or adapter with a non-compliant DC output voltage or it will burn the equipment. Select the proper UTP or STP cable in order to construct the network. Use an unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 5e for 10/100Mbps.
Antaira Technologies - Industrial Ethernet Switches LNX-C500 Series User Manual V1.1 7. Technical Specifications Table 7.1 has the technical specifications for Antaira Technologies’ LNX-C500 series: 5-port industrial unmanaged Ethernet switch with 5*10/100Tx ports. Standards Switch IEEE 802.3 10Base-T 10Mbit/s Ethernet IEEE 802.