Owner`s manual

COOKTOP IGNITER
SHORE #2
12 V.D.C.
PORT ENG.
START
BATTERY
30a.
12V. ALTERNATOR
ANTARES 44 ELECTRICAL
ONE LINE DIAGRAM
EL-04-04
L
SHIP'S SERVICE
BATTERY SWITCH
350A. DUAL CIRCUIT
MONITORING ONLY
MONITORING ONLY
START BATTERY
SWITCH 300a.
CONT. RATED
DUAL CIRCUIT
START BATTERY
SWITCH 300a.
CONT. RATED
DUAL CIRCUIT
NAV. INSTRUMENTS TYPICAL,
FUSE & VALUES AS RECOMMENDED
12 V.D.C.
STBD. ENG.
START
BATTERY
15a.
30a. 120V.A.C.
PLUG
PROPANE SYSTEM
15a.
LIGHTING LOADS
15a.
L
80a.
5a.
SOLENOID
15a.
15a.
15a.
30a.
15a.
LOCAL CONTROL
30a.
80a.
15a.
15a.
15a.
15a.
15a.
TYPICAL FOR
GENERAL LOADS
30a.
30a.
12V.D.C. SOLAR
ARRAY
12 V.D.C.
GEN. START
BATTERY
INVERTER SUPPLY / CHARGE
MAIN PANEL SUPPLY SUPPLY
WATERMAKER
WINDLASS
REMOTE
SEE HELM
PANEL DRWG.
EL-04-07
30a.
30a.
SOLAR PANEL
REGULATOR
( LOCATED IN
HELM CONSOLE )
HELM PANEL
T.C.
FOR USE WITH
TWO 120 VAC 30a.
SHORE CORDS
BLOWER
ENGINE
INSTRUMENTS
DISPLAY
AUTOPILOT
ENGINE
INSTRUMENTS
3a.
GALLEY
CONTROL
DISPLAY
DISPLAY
RADAR
ANTENNA
CHARGER
/
INVERTER
REMOTE PANEL
CONTROLS SWITCH
ELECT. COMPT.
GEN SET
AUXILLARY
COOLING
WATER PUMP
STBD. ENG.
RM.
BREAKER
INTEGRAL
TO GEN SET
120 VAC IN
120 VAC OUT
5a.
ELECTRICAL COMPARTMENT
INVERTER
120 VAC
NAV AIDS COMPONENTS
SUBJECT TO OPTIONS,
DATALINK NOT DEPICTED
15a. 15a.
15a.
15a.
15a.
OUTLETS
"A" BUS, SUPPLIED BY
SHORE #1 OR GEN.
INVERTER
BUS CAN BE
SUPPLIED BY
SHORE #1,
GEN SET OR
INVERTER
OUTLETS
15a.
15a.
OUTLETS
15a.
A.C.
VOLTS
HELM CONTROL
FLOAT
SWITCHES
L
HELM CONSOLE
BILGE
PUMP
FLOAT
SWITCH
L
BILGE PUMP
SWITCHES
BILGE
ALARM
HELM CONTROL
(NEG. CIRCUIT)
5a.
GENERAL LOADS
AIR COND.
20a.
AIR COND.
WATER HEATER
AIR COND.
15a.
15a.
WATER HEATER
15a.
"B" BUS,
SUPPLIED BY
SHORE #1,
SHORE #2,
OR GEN.
12V. ALTERNATOR
D.C.
AMPS
D.C. PANEL
MAIN
100a.
CHARGE
COMBINER
BILGE PUMP
CIRCUITS
AUTOPILOT
PUMP
HELM SWITCHES
HELM SUPPLY
HELM SWITCHES
3a.
STARTER
PORT ENGINE
L
L
TYPICAL
CYLINDER
BREAKER VALUES AS RECOMMENDED
FOR MOTOR PROTECTION
NUMBER AS REQ.
12 V.D.C.
SHIP'S
SERVICE
BATTERIES
80a.
15a.
30a.
STARTER
10a.
SHEET
WINCH
STBD. ENGINE
INTERLOCKED
BREAKERS
CONNECT "A"
WITH EITHER
SHORE #1
OR GEN
120V.A.C.
GENERATOR
GEN
SHORE #1
40a.
30a. 120V.A.C.
PLUG
DIAGRAM FOR MASTERVOLT
INVERTER / CHARGER MODEL
WITH 50a. INPUT CAPACITY.
USE "SHORT BREAK" TERMINALS
FOR AC OUT
50a.
INTERLOCKED
BREAKERS
CONNECT "B"
WITH EITHER
SHORE #2
OR "A" AS ABOVE
A.C.
AMPS
SHORE #1 SUPPLY ILLUSTRATED
A & B SUPPLY ILLUSTRATED
30a.
30a.
AUTOPILOT
PROCESSOR
WINCH
RELAY
WINDLASS
RELAY
50a.
12.V. HELM
PANEL BUS,
12 BREAKERS
ANCHOR
WINDLASS
300a.
LIGHTING
BUSS BAR
TYPICAL
NOTES:
ARRANGEMENT FOR APPLICATION WITH UP TO 6 KW.
GEN. SET, (INTEGRAL BATTERY CHARGING),
CHARGE COMBINER ENGAGES ONLY ABOVE 13.2V.
(CHARGE PRESENT IN EXCESS OF DISCHARGE),
NO NORMAL START OR DISCHARGE FUNCTION ASSOCIATED
WITH THIS ITEM
OPTIONAL SYSTEMS SHOWN MAY NOT BE APPLICABLE
TO SPECIFIC VESSELS
LOADING OF "A" AND "B" A.C. BUS'S MAY BE BALANCED
TO PROVIDE BEST USE OF SHORE POWER & INVERTER
RESOURCES FOR SPECIFIC VESSELS
THIS DIAGRAM IS NOT INTENDED
TO ACCURATELY INDICATE
RELATIVE COMPONENT PLACEMENT
OR SEPARATION. CONNECTION
DISTANCES ARE DISTORTED
POWER SOURCES
LOADS
LOCAL CONTROL
GENERAL DRAWING
CONFIGURATION
LOAD DIAGRAMS DEPICTED ARE TYPICAL
AND WILL VARY WITH VESSEL EQUIPMENT
MAIN DISTRIBUTION PANEL, UPPER 12VDC SECTION
MAIN DISTRIBUTION PANEL, LOWER 120VAC SECTION
15a.
12V.D.C.
120 V.A.C.
GEN SET
REMOTE
CONTROL
INV./CHG.
REMOTE
PANEL
HALYARD
WINCH
FUEL
LIFT
PUMP
STBD. ENG.
RM.
12V.D.C.
120 V.A.C.
WINCH
RELAY
120 V.A.C.
12V.D.C.
12.V.D.C. PANEL BUS (24 BREAKERS)
ACTUAL BREAKER VALUES
AS REQ. FOR CONDUCTOR
OR MOTOR PROTECTION
SHORE #1
SHORE #2
D.C.
VOLTS
V. METER
SELECTOR
SWITCH
PARALLEL
A & B
LOCATED IN
MASTER
CABIN
LOCKER
33
12 VDC IN / CHARGE OUT
AUX.
CHARGE
3a.10a.
MONITORING ONLY
2a.
2a.
2a.
REV. 2, MAY 13, 2009
FIRST VESSEL USED 4430