Owner`s manual

BATTERY BANK MAY BE HEAVILY DISCHARGED,
ALTERNATORS MAY NOT MAINTAIN CHARGE
INVERT MODE ON,
CHARGE MODE INACTIVE
CONDITION 4:
SAILING,
INVERTER ON,
ENGINES OFF
BATTERY BANK MAY
BE HEAVILY DISCHARGED,
MONITORING ADVISED
THE DC CURRENT DRAW FROM THE BATTERIES WILL BE
APPROXIMATELY 11 TIMES THE AC CURRENT SUPPLIED
BY THE INVERTER, A 1500 WATT AC APPLIANCE WILL
DRAW APPROX. 150 AMPS FROM THE BATTERIES
Ah-TimeVolt-Amp
NOTE:
GEN SET START BATTERY RELIES ON ITS OWN
ALTERNATOR AS 12V SOURCE FOR ITS OPERATION
120V CURRENT - MAGENTA ARROW
12V CURRENT - BLUE ARROW
NO CURRENT - GREY ARROW
ON
TYPICAL
INV. BUS LOADS
"INV" BUS"A" BUS
SHORE 1
30 AMPS
ON
TYPICAL
"A" BUS LOADS
ON
TYPICAL
"A" BUS LOADS
ON
TYPICAL
"A" BUS LOADS
ON
TYPICAL
"B" BUS LOADS
ONON
TYPICAL
"A" BUS LOADS
SHORE 2
30 AMPS
ON
INVERTER FUNCTION
BYPASSED
ON
SWITCH POSITIONS
GENERATOR
50 AMPS
120V SOURCE
SELECTION
120V LOADS
SUPPLIED BY
INVERTER
"A" & "B" CIRCUITS CAN NOT
BE SUPPLIED FROM INVERTER
PARALLEL
A & B
TYPICAL
"A" BUS LOADS
ON
"B" BUS
INVERTER/CHARGER REMOTE PANEL
TYPICAL
INV. BUS LOADS
CHARGER
TYPICAL
"B" BUS LOADS
ON
MASTERVOLT
ON
INVERTER
INVERTER/CHARGER
PERFORMS EITHER
FUNCTION, NOT
SIMULTANEOUSLY
SHORE
POWER #1
SHORE
POWER #2
GEN SET
CONVERTS
120V TO 12V
CONVERTS
12V TO 120V
BATTERY
CHARGER
TYPICAL
INV. BUS LOADS
TYPICAL
"B" BUS LOADS
TYPICAL
"A" BUS LOADS
ON
ON
INVERTER CHARGER CONTROL
INVERTER
12VDC CIRCUITS ABOVE
120VAC CIRCUITS BELOW
ONLY THE THREE UPPER RIGHT
CIRCUITS COMPRISING THE
INVERTER BUS ARE
SUPPLIED BY THE INVERTER,
O
N
O
N
O
N
O
N
O
N
O
N
12V DISTRIBUTION BREAKERS
O
N
O
N
O
N
O
N
O
N
O
N
O
N
LIMIT
12V LOADS
AS
PRACTICAL
O
N
O
N
O
N
SOLAR PANEL CHARGE CONTRIBUTION
IS UNLIKELY TO BE SUFFICIENT FOR
MAINTENANCE OF CURRENT FLOW
TO INVERTER
START
BATTERY
12V
ALTERNATOR
START
BATTERY
12V
ALTERNATOR
SOLAR
PANELS
IN "AUTO" MODE, COMBINER
CONVEYS RE-CHARGING
CURRENT ONLY
SHIP'S SERVICE
BATTERY BANK
12V POWER
RESERVOIR
CURRENT TO INVERTER
BYPASSES PANEL,
DC AMMETER WILL NOT
SHOW IT !
TC
ISSUED MAR. 19, 2009
CHARGE COMBINER
WILL NOT CONNECT
AS NO SUFFICIENT
CHARGE IS
AVAILABLE
SHORE #2 CAN ONLY
SUPPLY "B" BUS
ANTARES 44 ELECTRICAL
POWER FLOW DIAGRAMS
EL-04-14
OFF
ONON
AUTO
OFF
AUTO
CHARGE COMBINER