Manual

9
Step 2: Press and hold [DOWN] button
Step 3: Turn power on and release [DOWN] button when LCD display blinks
Step 4: Follow the menu instruction to pair or delete transmitter
Notes:
One machine can be controlled by up to 10 transmitters while one transmiter can be paired
with an unlimited number of machines.
Fluid
Use Antari FLC water-based fluid for the best performance for the M-4 Fogger. The
machine is tested and calibrated with this fluid to achieve the best output performance.
Warranty will be void if any other type of liquid is used, improper use of liquid may lead to
machine failure and malfunction.
Service and Maintenance
Do not allow the machine and fluid to become contaminated.
Regularly fill distilled water to fluid tank and run the machine to clean the system.
After cleaning, refill Antari fog fluids into fluid tank and make sure machine can
produce fog properly.
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
Excessive dust, liquid and dirt built up will degrade performance and cause
overheating.