User Manual

32 kHz
44.1 kHz
48 kHz
88.2 kHz
96 kHz
176.4 kHz
192 kHz
X
X
X
X
X
44.1 kHz
48 kHz
WC / 4
X
X
X
88.2 kHz
96 kHz
44.1 kHz
48 kHz
WC /2
32 kHz
44.1 kHz
48 kHz
88.2 kHz
96 kHz
176.4 kHz
192 kHz
WC
X
X
88.2 kHz
64 kHz
96 kHz
176.4 kHz
192 kHz
2 WC
X
X
X
X
X
X
X
X
176.4 kHz
128 kHz
192 kHz
4 WC
256 fs
256 fs
256 fs
256 WC
ALTERNATE SAMPLE RATE
WC/4 The output frequency is ¼ of WC 1-6
WC/2 The output frequency is ½ of WC 1-6
WC The output frequency is the same as on WC 1-6
2 WC The output frequency is 2x of WC 1-6
4 WC The output frequency is 4x of WC 1-6
256 WC The output is in Digidesign format, rate shown on the Frequency Display
8 Alternate Sample Rate Selector for Word Clock outputs 7 and 8.
Word clock outputs 7 and 8 are capable of outputting frequencies different from the signal
on WC 1-6. The first five settings of the switch choose frequencies that are multiples of the
output frequency of the audio generator. The final setting, 256 WC, configures the output to
generate the 256 FS Clock, a protocol used by some Digidesign components. These
settings are summarized below:
A red LED is present above each knob. When lit, it indicates that a valid sample rate is
selected. When flashing, the output has been configured to output at a frequency outside
the supported range (30kHz- 202 kHz).
For easy reference, the following chart indicates what frequencies outputs 7 and/or 8
transmit depending on what sample rates and knob settings are chosen. Although the
OCX-V can generate any frequency between 30kHz and 202 kHz, this chart is limited to
those most commonly used. Note a setting that would produce invalid output is marked
With an 'x'.
SAMPLE RATE