Datasheet

TM
ESD & PRODUCTION CONSUMABLES
ESD & PRODUCTION CONSUMABLES
TECHNICAL DATASHEET
0160003  UK  BUBBLE SHIELD BAGS | 11 MARCH 2022 4:48 PM V1
IMPORTANT: This data sheet and its contents (the “Information”) belong to Antistat or are licensed to it. No licence is granted for the use of it other than for information purposes in connection with the products to which it
relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but
Antistat assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the
products for their purpose and not make any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from
negligence or where Antistat was aware of the possibility of such loss or damage arising) is excluded. © 2021 Antistat.
To request a quotation or for more information, please call +44 (0)1473 836200
email info@antistat.co.uk or visit www.antistat.co.uk
TECHNICAL PROPERTIES TEST METHOD TYPICAL VALUES
Film Composition N/A PET-Al/PP
Outer layer Thickness Micron Meter 7 micron
Bubble layer Thickness Micron Meter 60 micron
Inner layer
Micron Meter 35 micron
Puncture Strength FTMS 101 14lbs
Tensile Strength ASTM D882 35lbs/inch width
Light Transmission ASTM D1003 41%
Interior Surface resistivity ASTM D257 10 Ohms
Exterior Surface resistivity ASTM D257 10 Ohms
Metalized Layer Resistivity ASTM D257 8 Ohms
Static Decay EIA-541 0.2secs
Remains Voltage EIA-541 24V
Physiological clearance certificate of used raw material Bgvv, Eu, FdA Ye s
The following results were taken under the following environmental test conditions:
Temperature: 22.3ºC / Humidity: 47.5%
TEST CONDITIONS
The following results were taken under the following environmental test conditions:
Temperature: 22.3ºC / Humidity: 47.5%
TEST ITEM TEST METHOD MEASURED EQUIPMENT(S) MDL
Lead (Pb) IEC 62321:2008 Ed.1 Sec.8 ICP-OES 2mg/kg
Cadmium (Cd) IEC 62321:2008 Ed.1 Sec.8 ICP-OES 2mg/kg
Mercury (hg) IEC 62321:2008 Ed.1 Sec.7 ICP-OES 2mg/kg
Hexavalent Chromium (Cr(Vi)) IEC 62321:2008 Ed.1 Annex C UV-Vis 2mg/kg
Polybrominated Biphenyls (PBBs) IEC 62321:2008 Ed.1 Annex A GC-MS 5mg/kg
Polybrominated Biphenyl Ethers (PBdEs) IEC 62321:2008 Ed.1 Annex A GC-MS 5mg/kg
TECHNICAL DATASHEET