User Manual
10 11
The Dionic XT Series features an Integrated PowerTap® and USB ports on the side of the battery to power camera accessories.
The PowerTap® allows for convenient deployment of up to 12 Amps of DC current for various parallel devices. The USB port supplies a regulated 5 volts
and maximum 2 Amps current and may be used for charging mobile devices.
Will deliver a high rate charge matched to the
capabilities of the battery (typically a one or two
hour rate, depending on battery type). During
this stage, six separate cuto methods are in
operation, simultaneously, ensuring the fastest,
safest charge for that battery.
Charging is a BALANCING or “stabilizing” mode
which calculates each battery pack type to oset
any imbalance of the battery’s cells, created by
unequal self-discharge or any capacity mismatch
of the individual cells in the pack. This stage can
vary in duration from zero to as much as 16 hours,
depending on the condition of the battery. The
Stage Two charge reduces current automatically
as the battery charges maintaining the cells at a
safe voltage level. A battery will typically leave
Stage Two in 2-4 hours under average operating
conditions.
Charging is the Anton/Bauer exclusive Lifesaver®
maintenance mode. This patented pulse routine
keeps batteries fully charged, free from self-
discharge - indefinitely - without damaging heat
associated with a so-called “trickle charge”. The
Stage Three programming monitors the self-
discharge of the battery, providing charge only
when the battery self-discharges to about 95% of
its capacity.