Owner`s manual

5
SERVICE
In the event a HyTRON battery fails to deliver acceptable
performance, it must be returned to Anton/Bauer. No other facility is
qualied and equipped to service the HyTRON battery or calibrate
the electronic components and sensors. Any attempt by the user
or any other unauthorized persons to service this battery will surely
result in improper calibration of the electronic components resulting
in severe battery damage and/or safety hazards, including potential
personal injury and/or damage to property. Any such attempt will
void any/all unconditional warranties.
Therefore:
1. NEVER attempt to service this battery. If there is a problem,
send this battery only to Anton/Bauer for evaluation.
2. NEVERATTEMPTTOOPENTHISBATTERY.The electronic
circuits inside the battery can be damaged causing malfunction
and/or potential hazard to person and property.
3. NEVER attempt to replace the cells in this battery – it cannot
be rebuilt. At the end of its useful life contact the Anton/Bauer Field
Support Group.
PRECAUTIONS
1. Donotexposethisbatterytohightemperatures(above
50°C/120°F).Thisincludesstorageindirectsunlight,incars
inhotweather,orincloseproximitytoheatingdevices.This
maycauseelectrolyteleakage,impairedperformanceand
shorteningofbatteryservicelife.
2. Whennotusingthebatteryforprolongedperiods,the
batteryshouldbechargedtoapproximately50%capacity
andremovedfromthecharger.Longtermstorageinthefull
chargestatewillresultindeteriorationofcapacity,whichis
unrecoverableinsubsequentuse.
3. AllNickelMetalHydridebatterieshaveanitelife.Ifthe
batteryexhibitsnoticeablyshortenedrun-timethebattery
shouldbereplacedimmediately.Shortenedrun-timeis
indicativeofatleastonecellhavingreachedendoflife.
UNDERNOCIRCUMSTANCESattemptto“recondition”this
batterybyrepeatedcharginganddischarging.
4. Thisbatterycontainsspecializedelectroniccircuits,which
aredesignedtoprotecttheNiMHcellsfromovercharge,
overdischargeandovercurrent.Redundantprotection
devicesaredesignedtooperateifthebatteryvoltage
isabnormallyhighorlowandifthetemperatureofthe
batteryexceedsoperatingspecications.Theseelectronic
devicescanbedamagedifthebatteryissubjecttoabuse
ordamage.Donotuseabatterythathasbeensubjectedto
excessivemechanicalshockorwaterdamage.
5. Donotdrop,punctureorcrushthisbattery.Donotusethe
batteryifthecaseisdamagedorbroken.
SPECIFICATIONS
HyTRON140
OUTPUTVOLTAGE
14.4v Nominal
12.4 ~ 16.8 VDC Operating
CAPACITY
140 WH Nominal
(10 AH Rated)
FUSE
Internal 12.5 amp/125 volt
RECOMMENDEDOPERATION
(MAXIMUM DISCHARGE RATE)
15 - 100 watts
1
(175 watts)
TYPICALRUN-TIME
@ 20w - 7 hrs.
@ 25w – 5.6 hrs.
@ 40w – 3.5 hrs.
WEIGHT
5.5 lbs. (2.5 kg)
SIZE
5.45 x 4.75 x 2.90”
(13.84 x 12.06 x 7.37 cm)
OPERATINGTEMPERATURE
-30° - +50° C
HyTRON100
OUTPUTVOLTAGE
14.4v Nominal
12.4 ~ 16.8 VDC Operating
CAPACITY
100 WH Nominal
(7 AH Rated)
FUSE
Internal 12.5 amp/125 volt
RECOMMENDEDOPERATION
(MAXIMUM DISCHARGE RATE)
15 - 100 watts
1
(175 watts)
TYPICALRUN-TIME
@ 20w - 5 hrs.
@ 25w – 4 hrs.
@ 40w – 2.5 hrs.
WEIGHT
5.5 lbs. (2.5 kg)
SIZE
5.45 x 4.75 x 2.90”
(13.84 x 12.06 x 7.37 cm)
OPERATINGTEMPERATURE
-30° - +50° C
HyTRON50
OUTPUTVOLTAGE
14.4v Nominal
12.4 ~ 16.8 VDC Operating
CAPACITY
50 WH Nominal
(3.5 AH Rated)
FUSE
Internal 7 amp
RECOMMENDEDOPERATION
(MAXIMUM DISCHARGE RATE)
15 - 50 watts
1
(75 watts)
TYPICALRUN-TIME
@ 10w - 5 hrs.
@ 25w – 2.5 hrs.
@ 25w – 2 hrs.
WEIGHT
2.0 lbs. (0.9 kg)
SIZE
5.25 x 3.50 x 2.13”
(13.39 x 8.89 x 5.39 cm)
OPERATINGTEMPERATURE
-30° - +50° C
1
Routine use of a battery at discharge rates greater than the battery rating
can reduce overall service life. Always select the proper size battery for your
application.