Specifications

Project No.:ZKT-211130L6532E
Page 16 of 38
4.2 RADIATED EMISSION MEASUREMENT
Test Requirement:
FCC Part15 C Section 15.209
Test Method:
ANSI C63.10:2013
Test Frequency Range:
9kHz to 25GHz
Test site:
Measurement Distance: 3m
Receiver setup:
Frequency
Detector
RBW
VBW
Value
9KHz-150KHz
Quasi-peak
200Hz
600Hz
Quasi-peak
150KHz-30MHz
Quasi-peak
9KHz
30KHz
Quasi-peak
30MHz-1GHz
Quasi-peak
100KHz
300KHz
Quasi-peak
Above 1GHz
Peak
1MHz
3MHz
Peak
Peak
1MHz
10Hz
Average
4.2.1 RADIATED EMISSION LIMITS
Frequencies
(MHz)
Field Strength
(micorvolts/meter)
Measurement Distance
(meters)
0.009~0.490
2400/F(KHz)
300
0.490~1.705
24000/F(KHz)
30
1.705~30.0
30
30
30~88
100
3
88~216
150
3
216~960
200
3
Above 960
500
3
The field strength of emissions from intentional radiators operated within these frequency bands
shall comply with the following:
LIMITS OF RADIATED EMISSION MEASUREMENT
FREQUENCY (MHz)
Limit (dBuV/m) (at 3M)
PEAK
AVERAGE
Above 1000
74
54
Notes:
(1)
The limit for radiated test was performed according to FCC PART 15C.