MANUFACTURING NUMBERS: 9100400 9100402 9100410 9100412 � L IS T ED �� AN TACO BELL STEAMER I T A T IO L IS N S T ED �� Models TBS-1X & TBS-2X P/N 1010698 Rev.
TACO BELL STEAMER TBS-2X & TBS-1X TABLE OF CONTENTS Owner Information .....................................................2 General......................................................................2 Warranty Information .................................................2 Service/Technical Assistance ....................................3 Model Designation.....................................................3 Manufacturing Number ..............................................
TACO BELL STEAMER TBS-2X & TBS-1X OWNER INFORMATION (continued) Service/Technical Assistance Authorized Service Agency If you experience any problems with the installation or operation of your unit, contact your local Roundup Authorized Service Agency. They can be found in the service agency directory packaged with the equipment. Name: Phone No.: Address: Fill in the information below and have it handy when calling your authorized service agency for assistance.
TACO BELL STEAMER TBS-2X & TBS-1X IMPORTANT SAFETY INFORMATION Throughout this manual, you will find the following safety words and symbols that signify important safety issues with regards to operating or maintaining the equipment. WARNING WARNING GENERAL WARNING. Indicates information important to the proper operation of the equipment. Failure to observe may result in damage to the equipment and/or severe bodily injury or death. ELECTRICAL WARNING.
TACO BELL STEAMER TBS-2X & TBS-1X IMPORTANT SAFETY INFORMATION (continued) • WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH. - Electrical ground is required on this appliance. - Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician. - Do not use an extension cord with this appliance.
TACO BELL STEAMER TBS-2X & TBS-1X SPECIFICATIONS Electrical Ratings Model and Manufacturing Number Voltage Watts Amps Hertz TBS-2X 9100400 (per side) 208 3300 15.9 50/60 TBS-1X 9100410 208 3300 15.9 50/60 WARNING All electrical connections must be in accordance with local electrical codes and any other applicable codes. WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESULT IN SERIOUS INJURY OR DEATH. CAUTION The TBS-2X has two power cords.
TACO BELL STEAMER TBS-2X & TBS-1X INSTALLATION Unpacking CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes. 1. Remove unit and all packing materials from shipping carton. 2. The box should contain the following: • Taco Bell Steamer • Handle & Handle Guard (Qty. 2 for TBS-2X) • Water Quick Disconnect Kit (Qty.
TACO BELL STEAMER TBS-2X & TBS-1X INSTALLATION (continued) CAUTION Water pressure must not exceed 30 psi (2.1 kg/ cm2 or 207 kPa). Higher water pressures may cause poor performance or flooding. To reduce water pressure, install a water pressure regulator, and set water pressure between 20-30 psi (1.4 - 2.1 kg/cm2 or 138 - 207 kPa). To order a water pressure regulator from your authorized service center, order Roundup part no. 7000314. WARNING ELECTRICAL SHOCK HAZARD.
TACO BELL STEAMER TBS-2X & TBS-1X INSTALLATION (continued) NOTE: If steamer does not steam properly after calibration, refer to the Troubleshooting section of this manual. 8. With the unit positioned at the edge of its location surface (Edge of the counter, table, etc.) slide the steamer forward approximately 3” to expose the Water Volume Control on the button of the unit (Figure 7). NOTE: If the Calibration Kit is missing, use the Calibration Chart (Figure 8) to figure the approximate volume.
TACO BELL STEAMER TBS-2X & TBS-1X OPERATION (continued) Operating Instructions IMPORTANT: Steam generator must be calibrated before initial use. See the section titled Calibration in the Installation section of this manual. ����� Rocker Switch (Power On/Off) 1. Turn on the Rocker Switch (power On/Off) (Figure 3). �� 2. Allow the unit to preheat for approximately 20-30 minutes. ����� IMPORTANT: The green light will flash during warm-up.
TACO BELL STEAMER TBS-2X & TBS-1X MAINTENANCE WARNING Turn the unit off, disconnect the power source and allow the unit to cool down before performing any service or maintenance on the unit. The TBS2X has two power cords. Make sure both cords are disconnected. Chimney Top Cover CAUTION Chlorides or phosphates in cleansing agents (e.g. bleach, sanitizers, degreasers or detergents) could cause permanent damage to stainless steel equipment.
TACO BELL STEAMER TBS-2X & TBS-1X MAINTENANCE (continued) Monthly Maintenance 10. Clean Steam Chamber free of any product spills. Your steamer utilizes an open steam generator. Water sprayed onto the generator surface flashes into steam immediately, but the minerals in the water do not steam; they stay on the generator surface.
TACO BELL STEAMER TBS-2X & TBS-1X MAINTENANCE (continued) Slanted end of tube �� �� � �� �� � ��� �� ��� �� ��� ��� �� CA U T "H ION OT " �� �� CA UTI "H ON OT" �� � �� � ��� �� ��� �� ��� ��� �� Figure 5. Installing Calibration Tubes Figure 6. Water Measurement 5. Turn the Rocker Switch (power On/Off) to ON. 6. Press the Cycle Start button and operate the unit through two complete cycles to purge all air from the tubes. �� ����� �� � �� �� �� � � The cup should contain 0.8 oz.
TACO BELL STEAMER TBS-2X & TBS-1X TROUBLESHOOTING WARNING To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.
TACO BELL STEAMER TBS-2X & TBS-1X TROUBLESHOOTING (continued) Problem Possible Cause(s) Corrective Action Solenoid Valve is leaking due to debris trapped within its plunger and seat. Disassemble the Solenoid Valve and clean out the plunger. Reassemble and test. If the a leak is still present, replace the Solenoid Valve. Solenoid Valve is installed incorrectly. If the Solenoid Valve was replaced, verify that the “IN” and “OUT” labels on the valve correspond to the water flow.
TACO BELL STEAMER TBS-2X & TBS-1X WIRING DIAGRAM ����� ���� ����� ��� ����� �� �� �� ��� ��������� ������ ��������� ���������� ������ ������ �� ��� ��������� ������ ������ �� ��� ��������� ��� ��� ��� ������ ������ �� ��� ��������� ������ ������ �� ��� ��������� ������� ����� �� �������� ����� �� ��� ������� �� �� � ��� � �� � � ����������� �� � ������ ��� � ��� � ����� � ��� � ��� �� �� � � ��� � �������� ���������� �� � ��� � � � ��� � � � ��� � � � �������� ��� � � �
TACO BELL STEAMER TBS-2X & TBS-1X REPLACEMENT PARTS � � �� �� �� �� � � � �� � � �� �� �� �� � � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� � � � � � �� �� P/N 1010698 Rev.
TACO BELL STEAMER TBS-2X & TBS-1X REPLACEMENT PARTS (continued) Item 1 Part No. 5 6 7 8 9 0011229 0011198 7000150 2100250 0503087 0503226 2100247 0503085 0503592 0300129 7000430 10 11 12 4010137 0021110 4060363 13 4060362 14 15 16 17 18 19 4010166 0503315 0020341 2100249 2100107 210K230 20 21 22 23 24 25 26 27 28 210K123 210K134 7000160 4050135 7000156 4040145 2000202 2000203 4030222 2190107 2080117 29 7000139 30 405K125 2 3 4 Description Item Qty. TBS-1X TBS-2X Top Cover Assy.
TACO BELL STEAMER TBS-2X & TBS-1X NOTES P/N 1010698 Rev.
LIMITED WARRANTY Equipment manufactured by A.J. Antunes & Co. Foodservice Equipment has been constructed of the finest materials available and manufactured to high quality standards. These units are warranted to be free from mechanical and electrical defects for a period of one year from date of purchase or 18 months from shipment from factory, whichever occurs first, under normal use and service, and when installed in accordance with manufacturer’s recommendations.