Operating instructions
VERTICAL CONTACT TOASTER VCT-20
10
P/N 1010719 Rev. C 12/99
A.J. Antunes & Co.
Safety Features
HI-LIMIT RESET BUTTON
A hi-limit thermostat will turn off electrical power to the
heater and control circuits if the unit overheats. To
reset this thermostat, allow sufficient time (10-15 min-
utes) for the unit to cool down, then depress the reset
button located on the rear of the unit (Figure 5).
If the unit requires continuous resetting, contact your
Roundup authorized service agency.
FAULT MESSAGES
• If the platen thermocouple is disconnected or
“open”, the display will read “HI” and the heating
circuit will turn off (Figure 10). The platen thermo-
couple must be reattached or replaced.
• If the platen heater temperature exceeds 591°F
(310°C) the display will read “HI” and the heating
circuit will turn off (Figure 10). After the toaster has
cooled down, the unit must be turned off, then back
on to restart. If this condition repeats, contact your
Roundup authorized service agency.
• If the auxiliary heating temperature exceeds 360°F
(182°C) the display will alternately flash “HI” and
the platen setpoint temperature (Figure 10). The
heating circuit will not turn off. The toaster must be
manually turned off and allowed to cool down.
After the toaster has cooled down, the unit must be
turned back on. If this condition repeats, contact
your Roundup authorized service agency.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
551
Figure 8. Adjusting Platen Heater
Temperature Setpoint
1. Press both keys at the same
time for 1 second to start
adjustment sequence.
2. Press TEMP UP key to raise
platen setpoint temperature.
3. Press TEMP DOWN key to
lower platen setpoint
temperature.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
336
Figure 9. Adjusting Auxiliary Heaters
Temperature Setpoint
1. Press both keys at the same
time for 1 second to start
adjustment sequence.
2. Press TEMP UP key to raise
auxiliary heaters setpoint
temperature.
3. Press TEMP DOWN key to
lower auxiliary heaters
setpoint temperature.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
HI
366
Figure 10. “HI” Fault Message
“HI” displayed if platen
temperature exceeds 591°F
(310°C) or if thermocouple is
disconnected or “open”.
Heating circuit will turn off.
“HI” and platen setpoint tem-
perature will alternately flash
if auxiliary heaters tempera-
ture exceeds 360°F (182°C).
Heating circuit will NOT turn
off.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
CHEC
“CHEC” will flash when
control compartment
ambient temperature is
excessive: 140°F (60°C) to
180°F (82°C). All heaters will
shut off.
Figure 11. “CHEC” Fault Message
OPERATION (continued)