5. Press interlock switch to rotate conveyors (Figure
14). Count to 10, then turn toaster off, and wipe
new section of belt wrap. Re-install the front and
rear cover assemblies.
6. Install the release sheet by draping it over both
sides of the platen with the crease centered
directly on the platen (Figure 13).
7. Install the heat shield (Figure 13). The heat
shield clips fit over the tip of the platen and retain
the release sheet.
FAULT MESSAGES (continued)
The temperature controller has an ambient temper-
ature sensor that will shut off all heating circuits if
the control compartment ambient temperature
becomes excessive: 140°F (60°C) to 180°F (82°C).
When this occurs, the temperature display will flash
“CHEC” (Figure 11). To restart the unit, ambient
temperature must drop to 140°F (60°C) and the
unit must be turned off, then back on.
If incoming power drops below 190 Volts, the toast-
er will shut down and the display will read “PO”
(Figure 12). To reset, power supply must be over
190 Volts, then the unit must be turned off and
back on.
Maintenance Schedule
DAILY
1. Turn off power to the toaster.
2. When the toaster is cool, follow the procedures
under
Cleaning the Release Sheet and Belt
Wraps.
3. Remove heat shield and bun chute. Wash in
back sink, sanitize and rinse.
4. Wipe down the outside of the toaster and allow to
air dry.
Cleaning the Release Sheet and BeltWraps
1. Turn the rocker switch to off, unplug the unit and
allow it to cool down.
2. Put on protective gloves. Remove heat shield
and release sheet (Figure 13).
3. Wipe release sheet with a clean, sanitized towel.
4. Remove front and rear conveyor cover assys.
(Figure 14). Wipe exterior of belt wraps with a
clean, sanitized towel.
MAINTENANCE
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
PO
PO will flash when
incoming power drops below
190 Volts. Toaster shuts
down.
Figure 12. PO Fault Message
WARNING
Turn the unit off, disconnect the power source and
allow the unit to cool down before performing any
service or maintenance on the unit.
CAUTION
To prevent damage to the unit, do not use abra-
sive cleaners on the release sheet or belt wrap.
Figure 13. Removing/Installing Release Sheet
Heat Shield
Platen
Release Sheet
OPERATION (continued)