Instructions
Table Of Contents
- 1 Preface
- 2 Safety
- 3 Preparation
- 4 About Anybus Communicator
- 5 Installation
- 6 Configuration Quick Guide
- 7 Communicator Configuration
- 7.1 Connecting the Communicator
- 7.2 Access the Built-In Web Interface From HMS IPconfig
- 7.3 Access the Built-In Web Interface From a Web Browser
- 7.4 Communicator Built-In Web Interface Overview
- 7.5 General Subnetwork Settings
- 7.6 About Transaction Templates
- 7.7 Build Transaction Templates
- 7.8 Nodes and Transactions
- 7.9 High Level Network Settings
- 7.10 Naming the Host
- 7.11 Station Name
- 7.12 I/O Data Map
- 7.13 Apply Configuration
- 7.14 Use an Existing Configuration
- 8 PLC Configuration
- 9 Verify Operation
- 10 Use Cases
- 11 Maintenance
- 12 Troubleshooting
- 13 Technical Data
- A Reference Guides
Use Cases
98 (124)
Create Write Parameter (0x02)
The Communicator writes values delivered from the PLC to the My Drive node.
1. Add an Empty template and select it.
2. Name the template Write parameter (0x02).
3. In the Frame editor Request area, add six frame fields with the following settings:
Request frame fields
Frame field
Name
Bytes/Length Type/
Checksum type
Endianess Fixed field Value (Hex)
Constant
Function code
1 Byte
N/A
Yes
N/A
Node address Node ID
1 Byte
N/A N/A N/A
Constant
Index
2
Word (two
bytes)
Big-endian
No Min 0
Max 1000
Constant
Sub index
1 Byte
N/A
No Min 0
Max 255
Data Data 2 Byte
N/A
Yes
N/A
Checksum Checksum
2 CRC
N/A N/A N/A
4. In the Frame editor Response area, add five frame fields with the following settings:
Response frame fields
Frame fields
Name Bytes
Type/
Checksum type
Endianess Fixed field Value (Hex)
Constant
Function code
1 Byte
N/A
Yes
N/A
Node address Node ID
1 Byte
N/A N/A N/A
Constant
Index
2
Word (two
bytes)
N/A
No Min 0
Max 1000
Constant
Sub index
1 Byte
N/A
No Min 0
Max 255
Checksum Checksum
2 CRC
N/A N/A N/A
Anybus
®
Communicator
™
User Manual