10.2.6 Set Up Node and Transactions
1. Add a node and select it.
2. In Node settings configure the node with the following settings:
Node settings Value
Node address
1
My Drive is set up as a node with Node address 1.
Name My Drive
Timeout time
1000 ms (default)
Reconnecting time
10000 ms (default)
Retries
0 (default)
3. Add four transactions to the My Drive node and configure them with the following settings:
My Drive contains the following parameters
Transaction name Transaction template Index Sub index
Control Word Write Parameter (0x02)
1 1
Speed Write Parameter (0x02)
1 2
Status Word
Read Parameter (0x01)
2 1
Actual Speed Read Parameter (0x01)
2 2