Instructions
Table Of Contents
- 1 Preface
- 2 Safety
- 3 Preparation
- 4 About Anybus Communicator
- 5 Installation
- 6 Configuration Quick Guide
- 7 Communicator Configuration
- 7.1 Connecting the Communicator
- 7.2 Access the Built-In Web Interface From HMS IPconfig
- 7.3 Access the Built-In Web Interface From a Web Browser
- 7.4 Communicator Built-In Web Interface Overview
- 7.5 General Subnetwork Settings
- 7.6 About Transaction Templates
- 7.7 Build Transaction Templates
- 7.8 Nodes and Transactions
- 7.9 High Level Network Settings
- 7.10 Naming the Host
- 7.11 Station Name
- 7.12 I/O Data Map
- 7.13 Apply Configuration
- 7.14 Use an Existing Configuration
- 8 PLC Configuration
- 9 Verify Operation
- 10 Use Cases
- 11 Maintenance
- 12 Troubleshooting
- 13 Technical Data
- A Reference Guides
Use Cases
103 (124)
10.3.5 Create Transaction Templates
Create Read Barcode Data Parameter
Before You Begin
The Communicator reads values delivered from to the Barcode Scanner node on to the PLC.
The Barcode Scanner sends data whenever it is available, without any request or handshake
from the Communicator.
In this example we have added three frame fields for the barcode data transaction:
• One Variable data frame for the length of the barcode.
We use a fixed value.
The maximum payload length is 31 (ASCII).
• The Barcode Scanner is configured to append:
– One Carriage Return character (CR) to the barcode.
So we create one Constant frame with the Value 13 (ASCII).
– One Line Feed character (LF) to the barcode.
So we create one Constant frame with the Value 10 (ASCII).