Use Cases
104 (124)
Procedure
1. Add an Empty consume template and select it.
2. Name the template Read Barcode Data.
3. In the Frame editor, add four frame field with the following settings:
Consume frame fields
Frame
fields
Name Type
Value Fixed field
Maximum
payload
length
Process
data
delimiter
Subnet
delimiter
End
pattern
Variable
data
Barcode
Data
N/A N/A
Yes, set
here
31 bytes
None None 0
Constant Carriage
Return
character
(CR)
Byte (1
byte)
13 Yes, set
here
N/A N/A N/A N/A
Constant
Line Feed
character
(LF)
Byte (1
byte)
10 Yes, set
here
N/A N/A N/A N/A
Anybus
®
Communicator
™
User Manual
SCM-1202-176 1.0 en-US