Instructions
Table Of Contents
- 1 Preface
- 2 Safety
- 3 Preparation
- 4 About Anybus Communicator
- 5 Installation
- 6 Configuration Quick Guide
- 7 Communicator Configuration
- 7.1 Connecting the Communicator
- 7.2 Access the Built-In Web Interface From HMS IPconfig
- 7.3 Access the Built-In Web Interface From a Web Browser
- 7.4 Communicator Built-In Web Interface Overview
- 7.5 General Subnetwork Settings
- 7.6 About Transaction Templates
- 7.7 Build Transaction Templates
- 7.8 Nodes and Transactions
- 7.9 High Level Network Settings
- 7.10 Naming the Host
- 7.11 Station Name
- 7.12 I/O Data Map
- 7.13 Apply Configuration
- 7.14 Use an Existing Configuration
- 8 PLC Configuration
- 9 Verify Operation
- 10 Use Cases
- 11 Maintenance
- 12 Troubleshooting
- 13 Technical Data
- A Reference Guides
Use Cases
105 (124)
Set Up Node and Transactions
1. Add a node and select it.
2. In Node settings configure the node with the following settings:
Node settings Value
Node address The Barcode Scanner is set up as a node with Node
address 1.
Name
Barcode Scanner
Timeout time
1000 ms (default)
Reconnecting time
1000 ms (default)
Retries
0 (default)
3. Add one transactions to the Barcode Scanner node and configure it with the following
settings:
The Barcode Scanner contains the following parameters
Transaction name Transaction template
Read Barcode Data Read Barcode Data Template
Check the I/O Data Map
The transactions from the Barcode Scanner is mapped as follows in the I/O data map page.
Status word and actual speed from My Drive to PROFINET
Address Barcode Scanner Parameter
0-31
The variable data, 31 bytes, are forwarded from the Barcode Scanner to the PLC.
Anybus
®
Communicator
™