3. Conguraon Conversion
The intended use of the conguraon conversion is to:
• convert custom protocols.
• get a new Communicator unit up and running quickly and then complete the conguraon in
the Communicator's built-in web interface.
NOTE
If standard Modbus RTU commands are imported, they are converted to custom request/response
transacons. The behavior of the standard Modbus RTU commands is preserved.
If you want to add addional commands you have to add them via the transacon templates in the
user interface (all Modbus commands are available)
Locate the conguraon le used with the Communicator Classic, that should be converted to work with the new
Communicator.
In the built-in web-interface of the new Communicator to be congured:
1. On the Files & Firmware page, click the Import Anybus Communicator Classic conguraon buon.
2. In the Import conguraon window, click Select le (.cfg).
NOTE
If there is an accompanying .cfx name le, it can also be selected and imported.
3. In the Open dialog box, browse to and select the conguraon le and click Open.
4. To import the conguraon le, click Import.
The conguraon is now imported in to the web interface of the new Communicator. A pop-up window will
appear, saying The import succeeded with the following messages. This window will present things that might
need tweaking or correcons.
Conguraon Conversion Replacing Communicator Classic with New Communicator