9.2. Communicator LED Indicators
NOTE
Before you can verify operaon you must congure the Communicator.
Figure 83. Communicator status (A), High level Network/Client (B), Subnetwork 2 (C) and (D) Security Switch
LED A LED B LED C LED D
Operaon status Gateway status EtherNet/IP - Adapter Subnetwork Security switch
O No power No power/No IP address No power/Subnetwork not
running/Node is switched
o via a control word
No power/Security switch is
unlocked
Green, ashing Startup phase EtherNet/IP online, no
connecons established
Running, one or more
nodes are oine
N/A
Green, solid Operaonal EtherNet/IP online, one
or more connecons
established
Running Security switch is locked
Red, solid N/A Duplicated EtherNet IP
address/Fatal error
N/A N/A
Red, ashing Invalid conguraon One or more connecons
med out
All nodes are oine N/A
Green/Red, ashing Power up self-test/
Firmware update/Firmware
recovery
N/A N/A N/A
9.2.1. Fatal Error and Excepon Error
Fatal error: A fatal error causes the Communicator rmware applicaon to crash in an uncontrolled manner.
Excepon error: An excepon error causes the Communicator to enter a controlled error state. The
Communicator rmware applicaon is sll running.
LED Fatal error Excepon error
A Red, solid Red, solid
B Red, solid O
C Red, solid O
D O O
Anybus
®
Communicator
- EtherNet/IP
to Modbus RTU/Serial Communicator LED Indicators