Manual
Table Of Contents
- Anybus® Communicator™ - EtherNet/IP™ to Modbus RTU/Serial
- Table of Contents
- 1. Preface
- 2. Safety
- 3. Preparation
- 4. About Anybus Communicator
- 5. Installation
- 6. Configuration Quick Guide
- 7. Communicator Configuration
- 7.1. Connect the Communicator
- 7.2. Access the Built-In Web Interface From HMS IPconfig
- 7.3. Access the Built-In Web Interface From a Web Browser
- 7.4. Communicator Built-In Web Interface Overview
- 7.5. General Subnetwork Settings
- 7.6. About Transaction Templates
- 7.7. Build Transaction Template
- 7.8. Nodes and Transactions
- 7.9. High Level Network Settings
- 7.10. I/O Data Map
- 7.11. Configuration Notes
- 7.12. Apply Configuration
- 7.13. To Use an Existing Configuration
- 7.14. To Use an Communicator Classic Configuration
- 8. PLC Configuration
- 9. Verify Operation
- 10. Use Cases
- 11. Maintenance
- 12. Troubleshooting
- 13. Technical Data
- 14. Reference Guides
Convert Between Big-Endian and Lile-Endian
To convert between big-endian and lile-endian you must reverse the byte order.
Figure 66. I/O data map, Endian swap
To reverse the byte order:
1. In the web-interface le sidebar menu, click I/O data map.
2. In the data map, select the transacon for which you want to do swap the byte order.
3. Select the endian swap type from the Endian swap drop-down menu.
Seng Descripon
No swapping Default seng
No swapping is performed on the data.
Bytes Swap 2 bytes
A B C D becomes B A D C
Words Swap 4 bytes
A B C D becomes C D A B
Bytes and words A B C D becomes D C B A
4. To apply the sengs, click Apply in the web-interface header, and follow the instrucons.
I/O Data Map Anybus
®
Communicator
™
- EtherNet/IP
™
to Modbus RTU/Serial
SCM-1202-152 Version 1.12 Page 79 of 133