Anybus® Wireless Bridge II™ STARTUP GUIDE SCM-1202-013/SP2167 1.
Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous product development.
Preparation 3 (16) 1 Preparation 1.1 About This Document This document describes how to install Anybus Wireless Bridge II and set up a basic configuration. For additional documentation, configuration examples, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support. 1.
Preparation 1.3 4 (16) Product Description Anybus Wireless Bridge II provides wireless communication over WLAN and/or Bluetooth® to wired networks.
Installation 5 (16) 2 Installation 2.1 Safety Caution This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Make sure that all medical devices used in proximity to this device meet appropriate susceptibility specifications for this type of RF energy. Caution The M12 power and LAN connectors must be provided with tool operated mechanical lock nuts that are tightened by the installer. This product is recommended for use in both industrial and domestic environments.
Installation 2.3 6 (16) Mechanical Installation Anybus Wireless Bridge II can be screw-mounted directly onto a flat surface or mounted on a standard DIN rail using the optional DIN mounting kit. All measurements are in mm. Anybus® Wireless Bridge II™ Startup Guide SCM-1202-013/SP2167 1.
Installation 2.4 7 (16) Connectors Power Connector (A-coded male M12) Pin 1 2 3 4 5 Function Power + (9–30 V) Digital Input Ground Power Ground Digital Input + (9–30 V) Functional Earth The digital input can be used for additional functionality with advanced configurations and to reset the unit. For more information please refer to the Anybus Wireless Bolt/Bridge II AT Reference Guide. If voltage is applied to the digital input for more that 10 seconds the unit will be reset to factory defaults.
Installation 2.
Installation 9 (16) Link Quality/Mode Indicators RSSI (WLAN Client) / Link Quality (Bluetooth PANU) LED A A B A B C A B C Description No connection RSSI/Link Quality < 25 % RSSI/Link Quality 25–50 % RSSI/Link Quality 50–75 % D RSSI/Link Quality > 75 % These LEDs are also used when selecting an Easy Config mode and to indicate update status in Recovery Mode. See Easy Config, p. 11 and Recovery Mode LED Indications, p. 10. Anybus® Wireless Bridge II™ Startup Guide SCM-1202-013/SP2167 1.
Installation 2.6 10 (16) MODE Button The MODE button can be used to restart or reset the unit as well as for selecting an Easy Config mode. When the unit is powered on, press and hold MODE for >10 seconds and then release it to reset to the factory default settings. Recovery Mode If the web interface cannot be accessed, the unit can be reset by starting in Recovery Mode and reinstalling the firmware using Anybus Firmware Manager II, which can be downloaded from www.anybus.com/support.
Configuration 3 11 (16) Configuration Anybus Wireless Bridge II is normally configured via the web interface or using one of the pre-configured Easy Config modes. Advanced configuration can be carried out by issuing AT commands via the web interface or over a Telnet or RAW TCP connection to port 8080. 3.1 Web Interface The web interface is accessed by pointing a web browser to the IP address of the unit. The default address is 192.168.0.99.
Configuration 3.2.1 12 (16) Easy Config Modes EC 1 LED A 2 3 4 5 A 7 Bluetooth PANU – B – Reset IP settings to factory defaults. Wait for automatic configuration. C Client WLAN AP B C Bluetooth NAP B C WLAN AP A A 8 9 D Bluetooth NAP A 10 11 A Description Configure as a client and scan for another client (PANU to PANU). Reset configuration to factory defaults. B C 6 Role D Bluetooth PANU B D (any) B D (any) Configure units in mode 4 as clients.
Configuration 3.3 13 (16) Factory Restore Any one of these actions will restore the factory default settings: • Clicking on Factory Restore on the System Settings page • Executing Easy Config Mode 2 • Issuing the AT command AT&F and then restarting the unit • Holding MODE pressed for >10 seconds and then releasing it • Applying voltage to the digital input for >10 seconds Default Network Settings IP Assignment IP Address Subnet Mask Default Gateway Internal DHCP Server Static 192.168.0.99 255.
Configuration 3.4 14 (16) Configuration Examples More examples can be found at www.anybus.com/support. 3.4.1 Ethernet Bridge via WLAN or Bluetooth® Configuration with Easy Config This example describes how to connect two Ethernet network segments via WLAN or Bluetooth using Easy Config. Configuration 1. Power on the first unit and wait for the LEDs to light up and go out, then press MODE and release it immediately. 2.
Technical Data 15 (16) 4 Technical Data 4.1 Hardware Specifications Order code AWB3000 Wired Interface type Ethernet Antenna 3 internal antennas: 2.4 GHz 2.4 GHz MIMO 5 GHz Maximum range 400 m (WLAN and Bluetooth) Dimensions (LxWxH) 93 x 68 x 33.2 mm Weight 120 g Operating temperature -40 to +65 °C Storage temperature -40 to +85 °C AWB3010 1 external antenna: 2.
This page intentionally left blank
COMPLIANCE SHEET This document does not include the complete instructions for the safe use of the described equipment. Make sure that you have read and understood the safety instructions in the user documentation for the described equipment before proceeding. Anybus® Wireless Bridge II™ Additional cer tification and compliance infor mation EMC Compliance (CE) This product is in compliance with the Radio Equipment Directive 2014/53/EU through conformance with the following standards.
Anybus® Wireless Bridge II™ Compliance Sheet 2 (3) FCC Compliance Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. this device may not cause harmful interference, and 2.
Anybus® Wireless Bridge II™ Compliance Sheet 3 (3) Other Certifications Contains MIC ID: R 204-510009 (indoor use only) IFETEL Marca: Anybus Modelo: AWB3 NOM-208-SCF1-2016 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. © 2019 HMS Industrial Networks SP2145 1.
This page intentionally left blank
COMPLIANCE SHEET This document does not include the complete instructions for the safe use of the described equipment. Make sure that you have read and understood the safety instructions in the user documentation for the described equipment before proceeding. Anybus® Wireless Bridge II™ Additional cer tification and compliance infor mation UL Ordinary Locations (Ord.Loc.
COMPLIANCE SHEET This document does not include the complete instructions for the safe use of the described equipment. Make sure that you have read and understood the safety instructions in the user documentation for the described equipment before proceeding. Anybus® Wireless Bridge II™ Additional cer tification and compliance infor mation UL Hazardous Locations (Haz.Loc.
Anybus® Wireless Bridge II™ Compliance Sheet 2 (3) • Group C: Flammable gas, flammable liquid-produced vapor or combustible liquid-produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value greater than or equal to 0.45mm or less than 0.75mm, or minimum igniting current ratio (MIC ratio) greater than 0.40 and less than or equal to 0.80.
Anybus® Wireless Bridge II™ Compliance Sheet 3 (3) • AVERTISSEMENT : RISQUE D'EXPLOSION - LA BORNE EXTERNE DOIT ÊTRE FIXÉE MÉCANIQUEMENT À L’AIDE D’UN OUTIL POUR ÉVITER TOUTE SÉPARATION INVOLONTAIRE. UNE SÉPARATION INVOLONTAIRE ALORS QUE L’APPAREIL EST SOUS TENSION PEUT ENTRAÎNER UNE EXPLOSION. • AVERTISSEMENT : RISQUE D'EXPLOSION - SI L’ÉQUIPEMENT EST UTILISÉ À L’EXTÉRIEUR, INSTALLER DANS UN BOÎTIER JUGÉ REPRÉSENTATIF DE L’UTILISATION PRÉVUE.
COMPLIANCE SHEET This document does not include the complete instructions for the safe use of the described equipment. Make sure that you have read and understood the safety instructions in the user documentation for the described equipment before proceeding.
Anybus® Wireless Bridge II™ Compliance Sheet • 2 (2) equipment protection level “Gc”: equipment for explosive gas atmospheres, having an “enhanced” level of protection, which is not a source of ignition in normal operation and which may have some additional protection to ensure that it remains inactive as an ignition source in the case of regular expected occurrences (for example failure of a lamp) Special Conditions of Use: • The equipment shall only be used in an area of at least pollution degree 2,
This page intentionally left blank
last page © 2019 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden info@hms.se SCM-1202-013/SP2167 1.