Anybus® Wireless Bridge II™ STARTUP GUIDE SCM-1202-013/SP2167 EN 1.
Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous product development.
Preparation 3 (16) 1 Preparation 1.1 About This Document This document describes how to install Anybus Wireless Bridge II and set up a basic configuration. For additional documentation, configuration examples, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support. 1.2 Product Description Anybus Wireless Bridge II provides wireless communication over WLAN and/or Bluetooth® to wired networks.
Preparation 1.3 4 (16) Model Name – Certification Identifier The model name is used to identify the product for certifications. It consists of a model prefix followed by two designators that describe the specific interface configuration and functionality.
Installation 2 5 (16) Installation Caution This equipment emits RF energy in the ISM (Industrial, Scientific, Medical) band. Make sure that all medical devices used in proximity to this device meet appropriate susceptibility specifications for this type of RF energy. Caution The M12 power and LAN connectors must be provided with tool operated mechanical lock nuts that are tightened by the installer. This product is recommended for use in both industrial and domestic environments.
Installation 2.1 6 (16) Dimensions All measurements are in mm. Anybus® Wireless Bridge II™ Startup Guide SCM-1202-013/SP2167 EN 1.
Installation 2.2 7 (16) Connectors Power Connector (A-coded male M12) Pin 1 Function Power + (9–30 V) 2 Digital Input Ground 3 4 Power Ground Digital Input + (9–30 V) 5 Functional Earth Signal wiring for the digital input must be carried in the same cable as power and functional earth if wiring length exceeds 3 meters.
Installation 2.
Configuration 3 9 (16) Configuration Anybus Wireless Bridge II can be configured via the web interface or using one of the pre-configured Easy Config modes. Advanced configuration can be carried out by issuing AT commands via the web interface or over a Telnet or RAW TCP connection to port 8080. 3.1 The Web Interface The web interface is accessed by pointing a web browser to the IP address of the unit. The default address is 192.168.0.99.
Configuration 3.2 10 (16) Easy Config 1. Power on the unit and wait for the Link Quality LEDs to light up and go out again, then immediately press and release the MODE button. 2. Press MODE repeatedly to cycle through the Easy Config modes until the desired mode is indicated by the A-B-C-D LEDs. 3. Within 20 seconds of step 2, press and hold MODE for 2 seconds. When the button is released the unit will restart in the selected mode. 3.2.
Configuration 3.3 11 (16) Factory Restore Any one of these actions will restore the factory default settings: • Holding MODE pressed for >10 seconds and then releasing it • Executing Easy Config Mode 2 • Clicking on Factory Restore on the System Settings page • Issuing the AT command AT&F and then restarting the unit Default Network Settings IP Assignment Static IP Address Subnet Mask Default Gateway 192.168.0.99 255.255.255.0 192.168.0.
Configuration 3.4 12 (16) MODE Button The MODE button can be used to restart or reset the unit as well as for selecting an Easy Config mode. ► Press and hold the button for >10 seconds and then release it to reset to the factory default settings (when the unit is powered on). ► Press and hold the button during startup to enter Recovery Mode.
Configuration 3.5 13 (16) Configuration Examples More examples can be found at www.anybus.com/support. 3.5.1 Ethernet Bridge via WLAN or Bluetooth® Configuration with Easy Config This example describes how to connect two Ethernet network segments via WLAN or Bluetooth using Easy Config. Configuration 1. Power on the first unit and wait for the LEDs to light up and go out, then press MODE and release it immediately. 2.
Technical Data 14 (16) 4 Technical Data 4.1 Technical Specifications Order code AWB3000 AWB3010 Wireless antenna Internal External Maximum range 400 m (WLAN and Bluetooth) Using an external antenna does not extend the range but allows separate placement of antenna and unit (e.g. if unit is placed in an enclosure). Wired Interface type Ethernet Communication See Anybus Wireless Bridge II Datasheet Dimensions (LxWxH) 93 x 68 x 33.
COMPLIANCE SHEET This document does not include complete instructions for the safe use of the described equipment. Make sure that you have read and understood the original user documentation for the equipment before proceeding. Anybus® Wireless Bridge II™ Additional certification and compliance information UL Ordinary Locations (Ord.Loc.
This page intentionally left blank
COMPLIANCE SHEET This document does not include complete instructions for the safe use of the described equipment. Make sure that you have read and understood the original user documentation for the equipment before proceeding. Anybus® Wireless Bridge II™ Additional certification and compliance information UL Hazardous Locations (Haz.Loc.) Anybus Wireless Bridge II modules are certified for use in hazardous locations in compliance with the following standards: • ANSI/ISA 12.12.
Anybus® Wireless Bridge II™ Compliance Sheet 2 (3) • Group C: Flammable gas, flammable liquid-produced vapor or combustible liquid-produced vapor mixed with air that may burn or explode, having either a maximum experimental safe gap (MESG) value greater than or equal to 0.45mm or less than 0.75mm, or minimum igniting current ratio (MIC ratio) greater than 0.40 and less than or equal to 0.80.
Anybus® Wireless Bridge II™ Compliance Sheet 3 (3) • AVERTISSEMENT : RISQUE D'EXPLOSION - LA BORNE EXTERNE DOIT ÊTRE FIXÉE MÉCANIQUEMENT À L’AIDE D’UN OUTIL POUR ÉVITER TOUTE SÉPARATION INVOLONTAIRE. UNE SÉPARATION INVOLONTAIRE ALORS QUE L’APPAREIL EST SOUS TENSION PEUT ENTRAÎNER UNE EXPLOSION. • AVERTISSEMENT : RISQUE D'EXPLOSION - SI L’ÉQUIPEMENT EST UTILISÉ À L’EXTÉRIEUR, INSTALLER DANS UN BOÎTIER JUGÉ REPRÉSENTATIF DE L’UTILISATION PRÉVUE.
This page intentionally left blank
COMPLIANCE SHEET This document does not include complete instructions for the safe use of the described equipment. Make sure that you have read and understood the original user documentation for the equipment before proceeding.
Anybus® Wireless Bridge II™ Compliance Sheet • 2 (2) equipment protection level “Gc”: equipment for explosive gas atmospheres, having an “enhanced” level of protection, which is not a source of ignition in normal operation and which may have some additional protection to ensure that it remains inactive as an ignition source in the case of regular expected occurrences (for example failure of a lamp) Special Conditions of Use: • The equipment shall only be used in an area of at least pollution degree 2,
This page intentionally left blank
last page © 2018 HMS Industrial Networks AB Box 4126 300 04 Halmstad, Sweden info@hms.se SCM-1202-013/SP2167 EN 1.