User's Manual

AnyDATA.NET Inc. AnyTime AnyPlace Any Wireless Data Solution
TM
5. Electrical Specifications
5.1 DC Electrical Specifications
5.1.1 Absolute Maximum Ratings
Operating the module under conditions that exceed those listed in the Absolute Maximum Ratings
table may result in damage to the module.
Absolute Maximum Ratings should be considered as limiting values. The module may not function
properly and should not be operated if any one of the parameters is not within its specified operating
range.
Table 5-1 Absolute Maximum Ratings
PARAMETER MIN MAX
UNITS
Storage Temperature
-50 +85 ºC
Voltage On Any Input or Output Pin
-0.8 +3.5 V
+VEXT_DC
-1.0 +5.0 V
Supply Voltage
BATT_INT -1.0 +4.4 V
Initializing Current
250 mA
Drop
No damages after 60-Inch drop over concrete floor
5.1.2 Recommended Operating Conditions
PARAMETER MIN TYP MAX
UNITS
+VEXT_DC +4.0
+4.5
+5.0 V
Supply Voltage
BATT_INT +3.4
+4.0
+4.3 V
Operating Temperature -30 +60 ºC
Operating Humidity
95% (50°C) Relative Humidity
5.1.3 Power Consumption
All Rights Reserved.
AD-2001-06-28 Ver 1.1
-29-
STANDBY
CONVERSATION
(Busy)
Idle Sleep
900mA (MAX)
110mA
+VEXT_DC : 9mA
BATT_INT : 1mA