4 Electrical Specifications
4.1 DC Electrical Specifications
4.1.1 Absolute Maximum Ratings
Operating the modem under conditions that exceed those listed in the Absolute Maximum
Ratings table may result in damage to the modem.
Absolute Maximum Ratings are limiting values, and are considered individually. While
All other parameters are within their specified operating ranges. Functional operation of
the modem under any of the conditions in the Absolute Maximum Ratings table is not
implied.
PARAMETER MIN MAX UNITS
Storage Temperature -40 +80
Voltage On Any Input or Output Pin -0.5 +3.7 V
Supply Voltage +7.0 V
Initializing Current 100 mA
Drop
No damages after 60-Inch drop over
concrete floor